When.com Web Search

  1. Ads

    related to: gfci vs weatherproof outlet for house plugs installation

Search results

  1. Results From The WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    An outlet is defined by the NEC as "a point in the wiring system at which current is taken to utilization equipment". [1] This definition includes receptacles, lighting, motors, etc. Ordinary switches control but do not consume electricity, and therefore are not defined as outlets in this sense.

  4. Electrical outlet tester - Wikipedia

    en.wikipedia.org/wiki/Electrical_outlet_tester

    A receptacle tester being used to check for some types of improper wiring of an outlet. For this particular tester, proper wiring is indicated by the two yellow lights. The outlet tester checks that each contact in the outlet appears to be connected to the correct wire in the building's electrical wiring. It can identify several common wiring ...

  5. Earth-leakage circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    If the wrong type was used on an installation, the level of protection given could be substantially less than that intended, in particular the voltage operated type can only protect against faults or shocks to metalwork connected to the circuit ground, connected to the VO-ELCB, it cannot detect current leaving a live wire and running to ground ...

  6. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    A safer and more reliable alternative identified in the US and Canadian electrical codes is to replace the outlet with a Ground Fault Circuit Interrupter (GFCI) breaker outlet. [3] Cheater plugs are also used to break ground loops in audio systems. [5] This practice has been condemned as disregarding electrical safety.

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    The 20 A plug has a blade rotated 90° (opposite blade from what would be the "line" blade on a 2-15 or 5-15 plug. This prevents accidental insertion of plugs into outlets that use different voltages), and the 6-20R receptacle has a T-shaped hole to accept both 6-15P and 6-20P plugs (similar to the 5-20R receptacle accepting 5-15P and 5-20P plugs).