A typical motor start capacitor. A motor capacitor [1] [2] is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run ...
A variation of the centrifugal switch used a changeover contact to ensure that the auxiliary windings remain in the circuit through a running capacitor. These motors are called two-value or capacitor start capacitor run motors. Centrifugal switches are found in many clothes dryers, supplying power to the motor in parallel with the start switch ...
The start capacitor is typically mounted to the side of the motor housing. These are called capacitor-start motors, and have relatively high starting torque. There are also capacitor-run induction motors which have a permanently connected phase-shifting capacitor in series with a second winding. The motor is much like a two-phase induction motor.
[19] [20] [21] A capacitor-start, capacitor-run motor has two separate capacitors, one for starting the motor, and another for running it, and has a centrifugal switch to disconnect the starting capacitor, or a back-EMF relay connected in parallel with the auxiliary winding of the motor. This motor provides high starting torque and high efficiency.
Capacitor-run induction motors have a permanently connected phase-shifting capacitor in series with a second winding. The motor is much like a two-phase induction motor. Motor-starting capacitors are typically non-polarized electrolytic types, while running capacitors are conventional paper or plastic film dielectric types.
A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the powertrain and electric current surge of the motor during start-up. This reduces the mechanical stress on the motor and shaft, as well as the electrodynamic stresses on the attached power cables and electrical distribution network ...
Genteq is the rebranding of Regal's GE ECM, GE Capacitors and GE Commercial Motors divisions, which occurred in 2009. [ 1 ] Genteq develops and manufactures electronically commutated motors (ECM) and capacitors for residential and light commercial heating and air conditioning ( HVAC ) systems.
A single-phase supply connected to an alternating current electric motor does not produce a rotating magnetic field; single-phase motors need additional circuits for starting (capacitor start motor), and such motors are uncommon above 10 kW in rating.