  1. Results From The WOW.Com Content Network
  2. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Types used in commercial and industrial low-voltage distribution systems are rated to safely interrupt 200,000 amperes. The rating of power circuit breakers varies according to the application voltage; a circuit breaker that interrupts 50,000 amperes at 208 volts might be rated to interrupt only 10,000 amperes at 600 volts, for example.

  3. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    All circuit breaker systems have common features in their operation, but details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must first detect a fault condition. In small mains and low-voltage circuit breakers, this is usually done within the device itself. Typically ...

  5. Sulfur hexafluoride circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Sulfur_hexafluoride...

    Such circuit breakers have high carrying current rating (4 kA to 40 kA), and have a high breaking capacity (50 kA to 275 kA). They belong to the medium voltage range, but the transient recovery voltage withstand capability required by IEC/IEEE 62771-37-013 is such that the specifically developed interrupting principles must be used.

  6. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, ... Circuit Breakers:

  7. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...