ECGs are normally printed on a grid. The horizontal axis represents time and the vertical axis represents voltage. The standard values on this grid are shown in the adjacent image at 25mm/sec: [57] A small box is 1 mm × 1 mm and represents 0.1 mV × 0.04 seconds. A large box is 5 mm × 5 mm and represents 0.5 mV × 0.20 seconds.
If the electrical axis is between -30° and -90° this is considered left axis deviation. If the electrical axis is between +90° and +180° this is considered right axis deviation (RAD). RAD is an ECG finding that arises either as an anatomically normal variant or an indicator of underlying pathology.
QRS complex. Schematic representation of a normal sinus rhythm ECG wave. Diagram showing how the polarity of the QRS complex in leads I, II, and III can be used to estimate the heart's electrical axis in the frontal plane. The QRS complex is the combination of three of the graphical deflections seen on a typical electrocardiogram (ECG or EKG).
An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...
Ventricular tachycardia can occur due to coronary heart disease, aortic stenosis, cardiomyopathy, electrolyte imbalance, or a heart attack. [2][3] Diagnosis is by an electrocardiogram (ECG) showing a rate of greater than 120 beats per minute and at least three wide QRS complexes in a row. [2]
Einthoven's triangle. Einthoven's triangle is an imaginary formation of three limb leads in a triangle used in the electrocardiography, formed by the two shoulders and the pubis. [1] The shape forms an inverted equilateral triangle with the heart at the center. It is named after Willem Einthoven, who theorized its existence.
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...
The P wave is a summation wave generated by the depolarization front as it transits the atria. Normally the right atrium depolarizes slightly earlier than left atrium since the depolarization wave originates in the sinoatrial node, in the high right atrium and then travels to and through the left atrium. The depolarization front is carried ...