When.com Web Search

  1. Ads

    related to: chimney induced draft fan furnace

Search results

  1. Results From The WOW.Com Content Network
  2. Draft (boiler) - Wikipedia

    en.wikipedia.org/wiki/Draft_(boiler)

    Normally it is done with the help of a forced draft fan. [2] Induced draft: When air or flue gases flow under the effect of a gradually decreasing pressure below atmospheric pressure. In this case, the system is said to operate under induced draft. The stacks (or chimneys) provide sufficient natural draft to meet the low draft loss needs.

  3. Stack effect - Wikipedia

    en.wikipedia.org/wiki/Stack_effect

    The draft (draught in British English) flow rate induced by the stack effect can be calculated with the equation presented below. [12] [13] The equation applies only to buildings where air is both inside and outside the buildings. For buildings with one or two floors, h is the height of the building and A is the flow area of the openings.

  4. Furnace (central heating) - Wikipedia

    en.wikipedia.org/wiki/Furnace_(central_heating)

    A condensing gas furnace includes a sealed combustion area, combustion draft inducer and a secondary heat exchanger. The primary gain in efficiency for a condensing gas furnace, as compared to a mid-efficiency forced-air or forced-draft furnace, is the capture of latent heat from the exhaust gases in the secondary heat exchanger.

  5. Flue-gas stack - Wikipedia

    en.wikipedia.org/wiki/Flue-gas_stack

    The invention of fan-assisted forced draft in the early 20th century removed the industrial chimney's original function, that of drawing air into the steam-generating boilers or other furnaces. With the replacement of the steam engine as a prime mover, first by diesel engines and then by electric motors, the early industrial chimneys began to ...

  6. Boiler (power generation) - Wikipedia

    en.wikipedia.org/wiki/Boiler_(power_generation)

    Forced draught furnaces usually have a positive pressure. Balanced draught: Balanced draught is obtained through use of both induced and forced draft. This is more common with larger boilers where the flue gases have to travel a long distance through many boiler passes. The induced draft fan works in conjunction with the forced draft fan ...

  7. Forced-air gas - Wikipedia

    en.wikipedia.org/wiki/Forced-air_gas

    As a result it can be more easily routed through walls or floors. However, the condensing furnace is more expensive initially because of the extra induced-draft fan and condensate pump required, and the extra heat exchanger in the firebox. The heat exchangers may be damaged by corrosion or metal fatigue from many heating and cooling cycles.