When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  3. Working range - Wikipedia

    en.wikipedia.org/wiki/Working_range

    Each instrument used in analytical chemistry has a useful working range. This is the range of concentration (or mass) that can be adequately determined by the instrument, where the instrument provides a useful signal that can be related to the concentration of the analyte. [1] All instruments have an upper and a lower working limit.

  4. Colorimetry (chemical method) - Wikipedia

    en.wikipedia.org/wiki/Colorimetry_(chemical_method)

    A colorimeter is a device used to test the concentration of a solution by measuring its absorbance of a specific wavelength of light. To use this device, different solutions must be made, and a control (usually a mixture of distilled water and another solution) is first filled into a cuvette and placed inside a colorimeter to calibrate the machine.

  5. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    A check should first be done to ensure that the data should be seen is precise and accurate. Next, systematic daily checks such as analysing blanks, calibration standards, quality control check samples, and references must be performed to establish the reproducibility of the data.

  6. Laboratory quality control - Wikipedia

    en.wikipedia.org/wiki/Laboratory_quality_control

    An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well.

  7. Certified reference materials - Wikipedia

    en.wikipedia.org/wiki/Certified_reference_materials

    Reference materials are particularly important for analytical chemistry and clinical analysis. [2] Since most analytical instrumentation is comparative, it requires a sample of known composition (reference material) for accurate calibration.

  8. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  9. Blank (solution) - Wikipedia

    en.wikipedia.org/wiki/Blank_(solution)

    A blank solution is a solution containing little to no analyte of interest, [1] usually used to calibrate instruments such as a colorimeter. According to the EPA, the "primary purpose of blanks is to trace sources of artificially introduced contamination." [2] Different types of blanks are used to identify the source of contamination in the ...