Ads
related to: how to permanently remove condensation from furnace vent cap pvc hose- Efficient Furnaces
Save Big on Your Energy Bills
Lower Your Monthly Costs
- Reliable Furnaces
Pay Less for Great Service
Get a Furnace That Doesn't Quit
- Bespoke Furnace Offers
Save on Your Furnace Install
Don't Compromise On Quality
- Fast Furnace Installs
Stress-Free Furnace Installations
Pro Installers Near You
- Efficient Furnaces
Search results
Results From The WOW.Com Content Network
Construction is of the usual cast brass housing for plumbing parts, with a threaded connection to the pipework at the base. The top has a small outlet, usually hidden beneath a plastic dust cap. Internally there is a large hollow body, normally filled with water, and containing a float valve. The valve must always be installed vertically ...
The output of small condensate pumps is usually routed to a sewer, plumbing drain, or the outside world via PVC plastic tubing (condensate drain line). In some locales, condensate water is not permitted to enter a sewer system and must be directed to the outside of the house, usually into the leader/gutter downspout system, or the stormwater ...
Flue gas condensation is a process, where flue gas is cooled below its water dew point and the heat released by the resulting condensation of water is recovered as low temperature heat. Cooling of the flue gas can be performed either directly with a heat exchanger or indirectly via a condensing scrubber .
The condensate drips down and collects at the bottom, often in a built-in pan called a hotwell. The shell side often operates at a vacuum or partial vacuum, produced by the difference in specific volume between the steam and condensate. Conversely, the vapor can be fed through the tubes with the coolant water or air flowing around the outside.
Moreover, if the gas is not pure vapor, condensation will create a layer of gas with even lower vapor contents right next to the condensing surface, further lowering the boiling point. Therefore, the condenser's design must be such that the gas is well-mixed and/or that all of it is forced to pass very close to the condensation surface.
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...
However, in humid climates more energy is required to remove excess moisture from ventilation air. Kitchens and bathrooms typically have mechanical exhausts to control odors and sometimes humidity. Factors in the design of such systems include the flow rate (which is a function of the fan speed and exhaust vent size) and noise level.
PVC/CPVC – rigid plastic pipes similar to PVC drain pipes but with thicker walls to deal with municipal water pressure, introduced around 1970. PVC stands for polyvinyl chloride, and it has become a common replacement for metal piping. PVC should be used only for cold water, or for venting. CPVC can be used for hot and cold potable water supply.