  1. Results From The WOW.Com Content Network
  2. High-voltage direct current - Wikipedia

    en.wikipedia.org/wiki/High-voltage_direct_current

    Long distance HVDC lines carrying hydroelectricity from Canada's Nelson River to this converter station where it is converted to AC for use in southern Manitoba's grid. A high-voltage direct current (HVDC) electric power transmission system uses direct current (DC) for electric power transmission, in contrast with the more common alternating current (AC) transmission systems. [1]

  3. List of HVDC projects - Wikipedia

    en.wikipedia.org/wiki/List_of_HVDC_projects

    SEPRI (Electric Power Research Institute, China Southern Power Grid) is technically responsible for the entire project. Multiple suppliers are involved: three different VSC HVDC valve suppliers, two different HVDC land/sea cable suppliers and three different control & protection system/equipment suppliers. [28] [29] Nuozhadu - Guangdong

  4. HVDC converter - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter

    This makes voltage-source converters much easier to connect into a Multi-terminal HVDC system or "DC Grid". [27] HVDC systems based on voltage-source converters normally use the six-pulse connection because the converter produces much less harmonic distortion than a comparable LCC and the twelve-pulse connection is unnecessary.

  5. Quebec – New England Transmission - Wikipedia

    en.wikipedia.org/wiki/Quebec_–_New_England...

    450kV HVDC line (at right), on south side of Autoroute 20 east of the Nicolet station near Sainte-Eulalie, Quebec.. The Quebec – New England Transmission (officially known in Quebec as the Réseau multiterminal à courant continu (RMCC) [1] and also known as Phase I / Phase II [2] and the Radisson - Nicolet - Des Cantons circuit, [3] and known in New England as the Northern Pass) is a long ...

  6. Skagerrak (power transmission system) - Wikipedia

    en.wikipedia.org/wiki/Skagerrak_(power...

    The technology used was VSC, capable of black start. Although thyristor-based converters have a loss of only 0.7%, the IGBTs of VSC get close with a loss of 0.8 to 1%. Skagerrak 1 and 2 previously used Skagerrak 3 as a return cable, but 1 and 2 were again coupled so that Skagerrak 4 can use number 3 for returns. [18]

  7. Shetland HVDC Connection - Wikipedia

    en.wikipedia.org/wiki/Shetland_HVDC_Connection

    From there, a subsea cable runs to landfall at Noss Head in Caithness, with onward connection to an HVDC switching station north of the village of Staxigoe in Caithness. [ 6 ] [ 19 ] The route of the cable crosses TAT-10 , TAT-14 and Atlantic Crossing 1 telecommunication cables and the Piper – Flotta oil pipeline.

  8. Electrode line - Wikipedia

    en.wikipedia.org/wiki/Electrode_line

    HVDC electrodes are also used in some monopolar HVDC systems, for example the Italy–Corsica–Sardinia scheme. [4] In such systems the electrode line permanently carries the same current as the high-voltage conductor; however since the ground current is then only unidirectional, one of the electrodes (the cathode) can be of simpler design ...

  9. HVDC Vancouver Island - Wikipedia

    en.wikipedia.org/wiki/HVDC_Vancouver_Island

    HVDC Vancouver Island used metallic return, during monopolar operation, when current is lower than 600 A. Otherwise earth return was used. On Vancouver Island the line for metallic return is a monopolar line on wooden poles, which are used in some sections also by AC lines, running parallel to the main line of HVDC Vancouver Island.