The NFPA 72 standard uses the term Alarm Box, which could encompass a number of initiation mechanisms. [3] A few manual call points have been approved to UL/UL Canada standards. [4] [5] At the time of this writing, the pull station is still the most prominent design in this part of the world.
New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...
The NFPA 72 "covers the application, installation, location, performance, inspection, testing, and maintenance of fire alarm systems, supervising station alarm systems, public emergency alarm reporting systems, fire warning equipment and emergency communications systems (ECS), and their components."
From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
When the box is activated by turning a knob or pulling a hook, a spring-loaded wheel turns, tapping out a pulsed electrical signal corresponding to the box's number. [1] A receiver at fire headquarters announces the alarm through flashing lights or tones, or via a pen recorder, and the box number is matched to a list of box locations.
The next year, the committee published its initial report on a uniform standard, and went on to form the NFPA in late 1896. The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [6]
The results of the performed tests are also entered into the corresponding protocol which serves as the reason for making decision for issuing the certificate. Basing on the decision made, the applicant receives the Certificate of Conformity to Fire Safety or not. The list of the documents necessary for drawing up the Fire Safety Certificate: OGRN;