  1. Results From The WOW.Com Content Network
  2. Intermediate bulk container - Wikipedia

    en.wikipedia.org/wiki/Intermediate_bulk_container

    The most common IBC sizes of 275 and 330 US gallons fit on a single pallet of similar dimensions to pallets which hold 4 drums (220 US gallons), providing an extra 55-110 gallons of product in the IBC over drum storage, a 25%-50% increase for the same storage footprint. Additionally, IBCs can be manufactured to a customer's exact requirements ...

  3. Fire alarm system - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_system

    New codes and standards introduced around 2010, especially the new UL Standard 2572, the US Department of Defense's UFC 4-021-01 Design and O&M Mass Notification Systems, and NFPA 72 2010 edition Chapter 24, have led fire alarm system manufacturers to expand their systems voice evacuation capabilities to support new requirements for mass ...

  4. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    Depiction of New York World Building fire in New York City in 1882. Building codes in the United States are a collection of regulations and laws adopted by state and local jurisdictions that set “minimum requirements for how structural systems, plumbing, heating, ventilation, and air conditioning (), natural gas systems and other aspects of residential and commercial buildings should be ...

  5. Fire alarm control panel - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_control_panel

    Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...

  6. Fire alarm notification appliance - Wikipedia

    en.wikipedia.org/wiki/Fire_alarm_notification...

    From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...

  7. Manual fire alarm activation - Wikipedia

    en.wikipedia.org/wiki/Manual_fire_alarm_activation

    Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.

  8. MARPOL 73/78 - Wikipedia

    en.wikipedia.org/wiki/MARPOL_73/78

    Annex II covers the International Bulk Chemical Code (IBC Code) in conjunction with Chapter 7 of the SOLAS Convention. Previously, chemical tankers constructed before 1 July 1986 must comply with the requirements of the Code for the Construction and Equipment of Ships Carrying Dangerous Chemicals in Bulk (BCH Code).

  9. NFPA 72 - Wikipedia

    en.wikipedia.org/wiki/NFPA_72

    The NFPA 72 (National Fire Alarm and Signaling Code) is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.