When.com Web Search

  1. Ad

    related to: will compressor run without freon in house thermostat troubleshooting 2

Search results

  1. Results From The WOW.Com Content Network
  2. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A low refrigerant charge condition is often accompanied when the compressor is operational by a loud whooshing sound heard from the thermal expansion valve and the evaporator, which is caused by the lack of a liquid head right before the valve's moving orifice, resulting in the orifice trying to meter a vapor or a vapor/liquid mixture instead ...

  3. Freeze stat - Wikipedia

    en.wikipedia.org/wiki/Freeze_stat

    Air coil freeze stat. A freeze stat is a temperature sensing device for HVAC that monitors a heat exchanger to prevent its coils from freezing.Freeze stats can be used on both refrigerant-to-air, and refrigerant-to-liquid type heat exchangers and serve different purposes with similar goals for each.

  4. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    The DDC system is the "brain" of the HVAC system. It dictates the position of every damper and valve in a system. It determines which fans, pumps, and chiller run and at what speed or capacity. With this configurable intelligence in this "brain", we are moving to the concept of building automation. [2]

  5. Crankcase heater - Wikipedia

    en.wikipedia.org/wiki/Crankcase_heater

    The refrigerant migrates to the compressor crankcase where it is attracted to the compressor oil. This refrigerant vapor condenses and returns to a liquid in the off cycle. On the next start of the compressor, the oil is in a watery state and washes the bearings out, which leads to locked-up, frozen or totally burnt-out compressors.

  6. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    The compressor will keep operating at the same speed, but due to the bypass, the refrigerant mass flow circulating with the system is reduced, and thus the cooling capacity. This naturally causes the compressor to run uselessly during the periods when the bypass is operating. The turn down capacity varies between 0 and 100%. [85]

  7. Reversing valve - Wikipedia

    en.wikipedia.org/wiki/Reversing_valve

    A reversing valve is a type of valve and is a component in a heat pump, that changes the direction of refrigerant flow. By reversing the flow of refrigerant, the heat pump refrigeration cycle is changed from cooling to heating or vice versa. This allows a residence or facility to be heated and cooled by a single piece of equipment, by the same ...

  8. What's the best temperature to set your thermostat in the ...

    www.aol.com/whats-best-temperature-set...

    You can save as much as 10% a year on heating and cooling by adjusting the thermostat seven to 10 degrees for 8 hours a day from its normal setting.

  9. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    The thermostat controls the fan speed and/or the flow of water or refrigerant to the heat exchanger using a control valve. Due to their simplicity, flexibility, and easy maintenance, fan coil units can be more economical to install than ducted 100% fresh air systems (VAV) or central heating systems with air handling units or chilled beams .