When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    This may lead to ground faults on variable speed drives between the drive electronics and motor not being detected for example. Disadvantages of voltage-sensing devices over current-sensing: A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices.

  3. Electromagnetic compatibility - Wikipedia

    en.wikipedia.org/wiki/Electromagnetic_compatibility

    This helps for example to harmonize national standards across Europe. International standards organizations include: International Electrotechnical Commission (IEC), which has several committees working full-time on EMC issues. These are: Technical Committee 77 (TC77), working on electromagnetic compatibility between equipment including networks.

  4. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    For experimental characterization, a distinction must be made between contact resistance evaluation in two-electrode systems (for example, diodes) and three-electrode systems (for example, transistors). In two-electrode systems, specific contact resistivity is experimentally defined as the slope of the I–V curve at V = 0:

  5. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    For example, a circuit breaker with a 400 ampere frame size might have its over-current detection threshold set only 300 amperes where that rating is appropriate. For low-voltage distribution circuit breakers an international standard, IEC 60898-1, defines rated current as the maximum current that a breaker is designed to carry continuously.

  6. MCCB - Wikipedia

    en.wikipedia.org/wiki/MCCB

    MCCB may stand for: Mississippi Community College Board; Molded Case Circuit Breaker, a type of low-voltage circuit breaker; Mount Carmel College of Baler

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  8. Electronic symbol - Wikipedia

    en.wikipedia.org/wiki/Electronic_symbol

    Common circuit diagram symbols (US ANSI symbols) An electronic symbol is a pictogram used to represent various electrical and electronic devices or functions, such as wires, batteries, resistors, and transistors, in a schematic diagram of an electrical or electronic circuit. These symbols are largely standardized internationally today, but may ...

  9. Nyquist stability criterion - Wikipedia

    en.wikipedia.org/wiki/Nyquist_stability_criterion

    The Nyquist plot for () = + + with s = jω.. In control theory and stability theory, the Nyquist stability criterion or Strecker–Nyquist stability criterion, independently discovered by the German electrical engineer Felix Strecker [] at Siemens in 1930 [1] [2] [3] and the Swedish-American electrical engineer Harry Nyquist at Bell Telephone Laboratories in 1932, [4] is a graphical technique ...