When.com Web Search

  1. Ads

    related to: anion gap ratio calculator for pregnancy

Search results

  1. Results From The WOW.Com Content Network
  2. Delta ratio - Wikipedia

    en.wikipedia.org/wiki/Delta_Ratio

    Result 1: if there is a normal anion gap acidosis, the (AG – 12) part of the equation will be close to zero, the delta ratio will be close to zero and there is no mixed acid–base disorder. Your calculations can stop here. A normal anion gap acidosis (NAGMA) has more to do with a change in [Cl −] or [HCO − 3] concentrations.

  3. Anion gap - Wikipedia

    en.wikipedia.org/wiki/Anion_gap

    Anion gap can be classified as either high, normal or, in rare cases, low. Laboratory errors need to be ruled out whenever anion gap calculations lead to results that do not fit the clinical picture. Methods used to determine the concentrations of some of the ions used to calculate the anion gap may be susceptible to very specific errors.

  4. Urine anion gap - Wikipedia

    en.wikipedia.org/wiki/Urine_anion_gap

    The urine anion gap is an 'artificial' and calculated measure that is representative of the unmeasured ions in urine. Usually the most important unmeasured ion in urine is NH 4 + since it is the most important form of acid excretion by the kidney. [ 5 ]

  5. Base excess - Wikipedia

    en.wikipedia.org/wiki/Base_excess

    The serum anion gap is useful for determining whether a base deficit is caused by addition of acid or loss of bicarbonate. Base deficit with elevated anion gap indicates addition of acid (e.g., ketoacidosis). Base deficit with normal anion gap indicates loss of bicarbonate (e.g., diarrhea).

  6. Urine electrolyte levels - Wikipedia

    en.wikipedia.org/wiki/Urine_electrolyte_levels

    Urine electrolyte levels can be measured in a medical laboratory for diagnostic purposes. The urine concentrations of sodium, chlorine and potassium may be used to investigate conditions such as abnormal blood electrolyte levels, acute kidney injury, metabolic alkalosis and hypovolemia.

  7. Metabolic acidosis - Wikipedia

    en.wikipedia.org/wiki/Metabolic_acidosis

    Elevated protein (albumin, globulins) may theoretically increase the anion gap but high levels are not usually encountered clinically. Hypoalbuminaemia, which is frequently encountered clinically, will mask an anion gap. As a rule of thumb, a decrease in serum albumin by 1 G/L will decrease the anion gap by 0.25 mmol/L [citation needed]

  8. Reference range - Wikipedia

    en.wikipedia.org/wiki/Reference_range

    The standard definition of a reference range for a particular measurement is defined as the interval between which 95% of values of a reference population fall into, in such a way that 2.5% of the time a value will be less than the lower limit of this interval, and 2.5% of the time it will be larger than the upper limit of this interval, whatever the distribution of these values.

  9. High anion gap metabolic acidosis - Wikipedia

    en.wikipedia.org/wiki/High_anion_gap_metabolic...

    An anion gap is usually considered to be high if it is over 12 mEq/L. High anion gap metabolic acidosis is typically caused by acid produced by the body. More rarely, it may be caused by ingesting methanol or overdosing on aspirin. [1] [2] The delta ratio is a formula that can be