Search results
Results From The WOW.Com Content Network
Some have alleged that departures in normality in the process output significantly reduce the effectiveness of the charts to the point where it may require control limits to be set based on percentiles of the empirically-determined distribution of the process output [2]: 237 although this assertion has been consistently refuted. See Footnote 6.
Control charts are graphical plots used in production control to determine whether quality and manufacturing processes are being controlled under stable conditions. (ISO 7870-1) [1] The hourly status is arranged on the graph, and the occurrence of abnormalities is judged based on the presence of data that differs from the conventional trend or deviates from the control limit line.
The importance of knowing the natural process variation becomes clear when we apply statistical process control. In a stable process, the mean is on target; in the example, the target is the filling, set to 1 litre. The variation within the upper and lower control limits (UCL and LCL) is considered the natural variation of the process.
The control limits are set at three standard deviations on either side of the process mean, and are known as the upper control limit (UCL) and lower control limit (LCL) respectively. [2] If the process data plotted on the control chart remains within the control limits over an extended period, then the process is said to be stable. [2] [3]
Comparison of a linear power supply and a switched-mode power supply Linear power supply Switching power supply Notes Size and weight: 0.12 W/cm 3, 88 W/kg [28] Smaller than linear power supply. Compared to linear, a SMPS that is 20 kHz is 1/4, 100–200 kHz is 1/8, and 200 kHz–1 MHz types can be even smaller. [28]: 5–8
In current limit control (CLC) technique, duty cycle is controlled by controlling the load current between maximum and minimum values. The chopper is switched ON and OFF periodically so that the load current is maintained between predetermined maximum and minimum values. [1]
A switched-mode power supply operating at the current limit with the output short-circuited does not have increased power dissipation in the power transistor(s), so foldback current limiting is an application feature only rather than one that also prevents a load fault from also destroying the power supply. The safety benefit of reducing the ...
A regulated power supply is an embedded circuit; it converts unregulated AC (alternating current) into a constant DC. With the help of a rectifier it converts AC supply into DC. Its function is to supply a stable voltage (or less often current), to a circuit or device that must be operated within certain power supply limits.