In electronics and electrical engineering, a fuse is an electrical safety device that operates to provide overcurrent protection of an electrical circuit. Its essential component is a metal wire or strip that melts when too much current flows through it, thereby stopping or interrupting the current.
Switched and unswitched fused connection units, without sockets, use BS 1362 fuses for connection of permanently wired appliances to a socket-outlet circuit. They are also used in other situations where a fuse or switch (or both) is required, such as when feeding lighting off a socket-outlet circuit, to protect spurs off a ring circuit with ...
The fuses used in fuseboxes were either of the cartridge type, similar to those found in UK plugs, or replaceable fuse-wire held within two-prong enclosures. Other standard use of fuses include those within appliance plugs, and the main fuse located on the end of the service (supply) cable (at the service head). Breaker (circuit breaker, CB)
Single-phase ~230 V/40 A/9 kW fuse box for apartment rewiring. Each appliance and each room are highlighted into autonomous circuits - this apartment has 14 individual circuits. A relay is used to control the light fixtures in a large room. In new home construction, wiring for all electrical services can be installed before the walls are finished.
The ring is fed from a fuse or circuit breaker in the consumer unit. Ring circuits are commonly used in British wiring with socket-outlets taking fused plugs to BS 1363. Because the breaker rating is much higher than that of any one socket outlet, the system can only be used with fused plugs or fused appliance outlets.
For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...