When.com Web Search

  1. Ad

    related to: romex cable awg rating system free worksheet example

Search results

  1. Results From The WOW.Com Content Network
  2. Thermoplastic-sheathed cable - Wikipedia

    en.wikipedia.org/wiki/Thermoplastic-sheathed_cable

    White: 14 AWG wire (2.08 mm 2) for 15-amp circuits Yellow: 12 AWG wire (3.31 mm 2) for 20-amp circuits Orange: 10 AWG wire (5.26 mm 2) for 30-amp circuits Black: 6 or 8 AWG wire (13.3 mm 2 or 8.37 mm 2) for 60- and 45-amp circuits, respectively Grey: usage for underground installations, designated as "underground feeder" (UF) cables [4]

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    When the cross-sectional area of a wire is doubled, the AWG will decrease by 3. (E.g. two 14 AWG wires have about the same cross-sectional area as a single 11 AWG wire.) This doubles the conductance. When the diameter of a solid round wire is doubled, the AWG will decrease by 6. (E.g. 1 mm diameter wire is ≈18 AWG, 2 mm diameter wire is ≈12 ...

  4. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    For instance, instead of 14 AWG (American wire gauge) copper wire, aluminium wiring would need to be 12 AWG on a typical 15 ampere lighting circuit, though local building codes vary. Solid aluminium conductors were originally made in the 1960s from a utility-grade aluminium alloy that had undesirable properties for a building wire, and were ...

  5. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    The current British Standard for metallic materials including wire is BS 6722:1986, which is a solely metric standard, superseding 3737:1964, which used the SWG system. The IEC 60228 , used in most parts of the world, defines standard wire sizes based on their cross-sectional areas as expressed in mm 2 . [ 3 ]

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  7. Aluminum building wiring - Wikipedia

    en.wikipedia.org/wiki/Aluminum_building_wiring

    Also, the size of the aluminum wire needs to be larger compared to copper wire used for the same circuit due to the increased resistance of the aluminum alloys. For example, a 15 A branch circuit supplying standard lighting fixtures can be installed with either #14 AWG copper building wire or #12 AWG aluminum building wire according to the NEC ...

  8. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  9. National Electrical Code - Wikipedia

    en.wikipedia.org/wiki/National_Electrical_Code

    The temperature rating of a wire or cable is generally the maximum safe ambient temperature that the wire can carry full-load power without the cable insulation melting, oxidizing, or self-igniting. A full-load wire does heat up slightly due to the metallic resistance of the wire, but this wire heating is factored into the cable's temperature ...