When.com Web Search

  1. Ad

    related to: non contact mode of afm light control system for home

Search results

  1. Results From The WOW.Com Content Network
  2. Non-contact atomic force microscopy - Wikipedia

    en.wikipedia.org/wiki/Non-contact_atomic_force...

    Non-contact atomic force microscopy (nc-AFM), also known as dynamic force microscopy (DFM), is a mode of atomic force microscopy, which itself is a type of scanning probe microscopy. In nc-AFM a sharp probe is moved close (order of Angstroms ) to the surface under study, the probe is then raster scanned across the surface, the image is then ...

  3. Atomic force microscopy - Wikipedia

    en.wikipedia.org/wiki/Atomic_force_microscopy

    Non-contact mode AFM does not suffer from tip or sample degradation effects that are sometimes observed after taking numerous scans with contact AFM. This makes non-contact AFM preferable to contact AFM for measuring soft samples, e.g. biological samples and organic thin film. In the case of rigid samples, contact and non-contact images may ...

  4. Scanning probe microscopy - Wikipedia

    en.wikipedia.org/wiki/Scanning_probe_microscopy

    This interaction depends on the type of SPM, for scanning tunneling microscopy the interaction is the tunnel current, for contact mode AFM or MFM it is the cantilever deflection, etc. The type of feedback loop used is usually a PI-loop, which is a PID-loop where the differential gain has been set to zero (as it amplifies noise).

  5. Photoconductive atomic force microscopy - Wikipedia

    en.wikipedia.org/wiki/Photoconductive_Atomic...

    The non-contact feedback loop is used to control that changes in the oscillations of the cantilever. [37] The application of AFM on non-conducting samples (c-AFM) has in recent years evolved into the modification used for analysis of morphologies on the local scale, particularly morphologies at heterojunctions of multilayered samples.

  6. Near-field scanning optical microscope - Wikipedia

    en.wikipedia.org/wiki/Near-field_scanning...

    Constant force feedback mode is similar to the feedback mechanism used in atomic force microscopy (AFM). Experiments can be performed in contact, intermittent contact, and non-contact modes. In shear force feedback mode, a tuning fork is mounted alongside the tip and made to oscillate at its resonance frequency.

  7. Infrared Nanospectroscopy (AFM-IR) - Wikipedia

    en.wikipedia.org/wiki/Infrared_Nanospectroscopy...

    Traditional contact resonance AFM requires an external actuator to excite the cantilever contact resonances. In AFM-IR these contact resonances are automatically excited every time an infrared pulse is absorbed by the sample. So the AFM-IR technique can measure the infrared absorption by the amplitude of the cantilever oscillation response and ...

  8. Magnetic force microscope - Wikipedia

    en.wikipedia.org/wiki/Magnetic_force_microscope

    MFM images of 3.2 Gb and 30 Gb computer hard-drive surfaces. Comparison of Faraday-effect image (left) and MFM image (inset, lower-right) of a magnetic film. Magnetic force microscopy (MFM) is a variety of atomic force microscopy, in which a sharp magnetized tip scans a magnetic sample; the tip-sample magnetic interactions are detected and used to reconstruct the magnetic structure of the ...

  9. Electrostatic force microscope - Wikipedia

    en.wikipedia.org/wiki/Electrostatic_force_microscope

    In this mode the cantilever is oscillated at a resonant frequency of the cantilever and the AFM tip is held such that it only senses with long range electrostatic forces without entering the repulsive contact regime. In this non-contact regime, the electric force gradient causes a shift in the resonance frequency of the cantilever.