When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The prospective short-circuit current (PSCC), available fault current, or short-circuit making current is the highest electric current which can exist in a particular electrical system under short-circuit conditions. It is determined by the voltage and impedance of the supply system.

  3. IEEE 1584 - Wikipedia

    en.wikipedia.org/wiki/IEEE_1584

    IEEE 1584-2018 is an update to IEEE 1584-2002 and was developed to help protect people from arc-flash hazard dangers. The predicted arc current and incident energy are used in selecting appropriate overcurrent protective devices and personal protective equipment (generally abbreviated as PPE), as well as defining safe working distance. Since ...

  4. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    The second method of selecting PPE is to perform an arc flash hazard calculation to determine the available incident arc energy. IEEE 1584 provides a guide to perform these calculations given that the maximum fault current, duration of faults, and other general equipment information is known. Once the incident energy is calculated the ...

  5. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Since practical calculations involve a number of approximations and estimates, some judgment is required in applying the results of a short-circuit calculation to the selection of apparatus. [4] Making capacity i.e. maximum fault current , device can carry, if it is closed in to the fault should be considered.

  6. Power system protection - Wikipedia

    en.wikipedia.org/wiki/Power_system_protection

    Current and voltage transformers to step down the high voltages and currents of the electrical power system to convenient levels for the relays to deal with; Protective relays to sense the fault and initiate a trip, or disconnection, order; Circuit breakers or RCDs to open/close the system based on relay and autorecloser commands

  7. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That is why we calculate 130 V × √ 3 = 225 V. A three-phase final step-down transformer is then used. One house gets phases A and B, the next house gets phase B and C, the third house gets phase A and C.

  8. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    The power is transmitted from one end to another with the help of step-up and step down transformer. Most transmission lines are high-voltage three-phase alternating current (AC), although single phase AC is sometimes used in railway electrification systems .

  9. Arc fault - Wikipedia

    en.wikipedia.org/wiki/Arc_fault

    An arc fault is a high power discharge of electricity between two or more conductors. This discharge generates heat, which can break down the wire's insulation and trigger an electrical fire. Arc faults can range in current from a few amps up to thousands of amps, and are highly variable in strength and duration.