  2. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    Australian 3-Phase socket outlet, with both Earth and Neutral connections, rated at 20 A, IP56. Single-phase dual 10 Amp Australian socket outlets are seen in the background. The arrows point to slots in the 50 A socket.

  3. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A.

  4. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    This allows one to choose single-phase AC power at either 110–120 volts between phase and neutral or 220–240 volts between phase and phase. Since these two modes do not need three phases there is also a dark yellow-orange four-pin connector available designed for a single-phase 110–120 or 220–240 volt load.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  6. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  7. Ring circuit - Wikipedia

    en.wikipedia.org/wiki/Ring_circuit

    The IET Wiring Regulations permit an unlimited number of 13A socket outlets (at any point unfused single or double, or any number fused) to be installed on a ring circuit, provided that the floor area served does not exceed 100 m 2. In practice, most small and medium houses have one ring circuit per storey, with larger premises having more.