Droplet formation using a flow focusing device. [17] Diagram of flow focusing droplet formation device commonly used in microfluidic devices. Liquid flowing in from the left is pinched off into droplets by an oil flowing in from the top and bottom. [10] Two stream reagent addition using a flow focusing approach with a planar chip format. [18]
A second type is the capillary-tube type of thermal mass flow meter. Many mass flow controllers (MFC) which combine a mass flow meter, electronics and a valve are based on this design. Furthermore, a thermal mass flow meter can be built by measuring temperature differential across a silicon-based MEMS chip.
All mass flow controllers have an inlet port, an outlet port, a mass flow sensor and a proportional control valve. The MFC is fitted with a closed loop control system which is given an input signal by the operator (or an external circuit/computer) that it compares to the value from the mass flow sensor and adjusts the proportional valve ...
Instrumentation controls the operation of process columns. Instrumentation is used to monitor and control the process plant in the oil, gas and petrochemical industries. . Instrumentation ensures that the plant operates within defined parameters to produce materials of consistent quality and within the required specifica
The magnetic flow meter requires a conducting fluid, for example, water that contains ions, and an electrical insulating pipe surface, for example, a rubber-lined steel tube. If the magnetic field direction were constant, electrochemical and other effects at the electrodes would make the potential difference difficult to distinguish from the ...
A module with two input streams at the top, an AND output bucket in the middle, and an XOR output stream at the bottom.. Fluidics, or fluidic logic, is the use of a fluid to perform analog or digital operations similar to those performed with electronics.
An OCM is a small part of what is called the oil discharge monitoring and control system. The first part is the oil content meter. The first part is the oil content meter. The second is a flow meter which measures the flow rate of the water at the discharge pipe. [ 5 ]
The parallel-plate flow chamber, in its original design, is capable of producing well-defined wall shear-stress in the physiological range of 0.01-30 dyn/cm 2.Shear stress is generated by flowing fluid (e.g., anticoagulated whole blood or isolated cell suspensions) through the chamber over the immobilized substrate under controlled kinematic conditions using a syringe pump.