Thus, for a typical inductance (a coil of conducting wire), the flux linkage is equivalent to magnetic flux, which is the total magnetic field passing through the surface (i.e., normal to that surface) formed by a closed conducting loop coil and is determined by the number of turns in the coil and the magnetic field, i.e.,
If there is a finite change in flux linkage from one value to another (e.g. from to ), it can be calculated as: = () (If the changes are cyclic there will be losses for hysteresis and eddy currents. The additional energy for this would be taken from the input energy, so that the flux linkage to the coil is not affected by the losses and the ...
Armature reaction drop is the effect of a magnetic field on the distribution of the flux under main poles of a generator. [5] Since an armature is wound with coils of wire, a magnetic field is set up in the armature whenever a current flows in the coils.
The inductance is proportional to the square of the number of turns in the coil, assuming full flux linkage. The inductance of a coil can be increased by placing a magnetic core of ferromagnetic material in the hole in the center. The magnetic field of the coil magnetizes the material of the core, aligning its magnetic domains, and the magnetic ...
Schematic diagram. An induction coil consists of two coils of insulated wire wound around a common iron core (M). [1] [7] One coil, called the primary winding (P), is made from relatively few (tens or hundreds) turns of coarse wire. [7] The other coil, the secondary winding, (S) typically consists of up to a million turns of fine wire (up to 40 ...
But when the small coil is moved in or out of the large coil (B), the magnetic flux through the large coil changes, inducing a current which is detected by the galvanometer (G). [1] A diagram of Faraday's iron ring apparatus. Change in the magnetic flux of the left coil induces a current in the right coil. [2]
The alternating magnetic flux set up by the growler passes through the windings of the armature coil, generating an alternating voltage in the coil. A short in the coil creates a closed circuit that will act like the secondary coil of a transformer, with the growler acting like the primary coil.
In vector control, an AC induction or synchronous motor is controlled under all operating conditions like a separately excited DC motor. [21] That is, the AC motor behaves like a DC motor in which the field flux linkage and armature flux linkage created by the respective field and armature (or torque component) currents are orthogonally aligned such that, when torque is controlled, the field ...