When.com Web Search

  1. Ads

    related to: leaking shut off valve repair cost comparison free

Search results

  1. Results From The WOW.Com Content Network
  2. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Discharge from the relief device is an indication that either of the two check valves is 'passing' (leaking past their shutoff seats) or the relief valve itself is faulty. Some normal water use conditions may cause short episodes of discharge (this is why check one has a minimum passing value of relief +3.

  3. Valve leakage - Wikipedia

    en.wikipedia.org/wiki/Valve_leakage

    The importance of valve leakage depends on what the valve is controlling. For example, a dripping tap is less significant than a leak from a six-inch pipe carrying high-pressure radioactive steam. In the United States, the American National Standards Institute specifies six different leakage classes, with "leakage" defined in terms of the full ...

  4. Zone valve - Wikipedia

    en.wikipedia.org/wiki/Zone_valve

    Lower total cost of ownership when zone valve failure and repair costs are taken into account. More robust and reliable system. Simple mechanical and control design ("SPST thermostats") Redundancy: If one zone pump fails, the others can remain working; Far superior method of linking multiple heat sources. Such as gas and solid fuel in one system.

  5. Shutdown valve - Wikipedia

    en.wikipedia.org/wiki/Shutdown_valve

    A shutdown valve (also referred to as SDV or emergency shutdown valve, ESV, ESD, or ESDV; or safety shutoff valve) is an actuated valve designed to stop the flow of a hazardous fluid upon the detection of a dangerous event. This provides protection against possible harm to people, equipment or the environment.

  6. Partial stroke testing - Wikipedia

    en.wikipedia.org/wiki/Partial_stroke_testing

    The basic principle behind partial stroke testing is that the valve is moved to a predetermined position in order to determine the performance of the shut down valve. This led to the adaptation of pneumatic positioners used on flow control valve for use in partial stroke testing. These systems are often suitable for use on shutdown valves up to ...

  7. Pilot-operated relief valve - Wikipedia

    en.wikipedia.org/wiki/Pilot-operated_relief_valve

    In the PORV, the valve is held shut by piping a small amount of the fluid to the rear of the sealing disk, with the pressure balanced on either side. A separate actuator on the piping releases pressure in the line if it crosses a threshold. This releases the pressure on the back of the seal, causing the valve to open.

  1. Ads

    related to: leaking shut off valve repair cost comparison free