When.com Web Search

  1. Ads

    related to: generator power factor calculator 3 phase motor

Search results

  1. Results From The WOW.Com Content Network
  2. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    Power Quality Analyzers, often referred to as Power Analyzers, make a digital recording of the voltage and current waveform (typically either one phase or three phase) and accurately calculate true power (watts), apparent power (VA) power factor, AC voltage, AC current, DC voltage, DC current, frequency, IEC61000-3-2/3-12 Harmonic measurement ...

  3. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  4. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    When three-phase is needed but only single-phase is readily available from the electricity supplier, a phase converter can be used to generate three-phase power from the single phase supply. A motorgenerator is often used in factory industrial applications.

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    A three-phase motor is more compact and less costly than a single-phase motor of the same voltage class and rating, and single-phase AC motors above 10 hp (7.5 kW) are uncommon. Three-phase motors also vibrate less and hence last longer than single-phase motors of the same power used under the same conditions. [32]

  6. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    The fixed speed wind turbines without a power converter (also known as "Type 1" and "Type 2" [5]) cannot be used for voltage control. They simply absorb the reactive power (like any typical induction machine), so a switched capacitor bank is usually used to correct the power factor to unity. [7] Capability curve of a photovoltaic generator

  7. Induction motor - Wikipedia

    en.wikipedia.org/wiki/Induction_motor

    For example; a single-phase motor with 3 north and 3 south poles, having 6 poles per phase, is a 6-pole motor. A three-phase motor with 18 north and 18 south poles, having 6 poles per phase, is also a 6-pole motor. This industry standard method of counting poles results in the same synchronous speed for a given frequency regardless of polarity.

  8. Rotary phase converter - Wikipedia

    en.wikipedia.org/wiki/Rotary_phase_converter

    A basic three-phase induction motor will have three windings, each end connected to terminals typically numbered (arbitrarily) as L1, L2, and L3 and sometimes T1, T2, T3. A three-phase induction motor can be run at two-thirds of its rated horsepower on single-phase power applied to a single winding, once spun up by some means.

  9. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t