When.com Web Search

  1. Ads

    related to: how to calculate circulator size of water tank per person

Search results

  1. Results From The WOW.Com Content Network
  2. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    The traditional hot water recirculation system uses the existing cold water line as return line from the point of use located farthest from the hot water tank back to the hot water tank. The first of two system types has a pump mounted at the hot water heater while a "normally open" thermostatic control valve gets installed at the farthest ...

  3. Population equivalent - Wikipedia

    en.wikipedia.org/wiki/Population_equivalent

    Population equivalent (PE) or unit per capita loading, or equivalent person (EP), is a parameter for characterizing industrial wastewaters.It essentially compares the polluting potential of an industry (in terms of biodegradable organic matter) with a population (or certain number of people), which would produce the same polluting load.

  4. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    Feedwater pumps range in size up to many kilowatts and the electric motor is usually separated from the pump body by some form of mechanical coupling. Large industrial condensate pumps may also serve as the feedwater pump. In either case, to force the water into the boiler, the pump must generate sufficient pressure to overcome the steam ...

  5. Forced circulation boiler - Wikipedia

    en.wikipedia.org/wiki/Forced_circulation_boiler

    Water is introduced into the steam drum and is circulated around the boiler, leaving only as steam. What makes the forced circulation boiler different is its use of a secondary pump that circulates water through the boiler. The secondary pump takes the feed water going to the boiler and raises the pressure of the water going in.

  6. Circulating water plant - Wikipedia

    en.wikipedia.org/wiki/Circulating_Water_Plant

    A circulating water plant or circulating water system is an arrangement of flow of water in fossil-fuel power station, chemical plants and in oil refineries. The system is required because various industrial process plants uses heat exchanger , and also for active fire protection measures.

  7. Well control - Wikipedia

    en.wikipedia.org/wiki/Well_control

    The Equivalent Circulating Density (ECD) is defined as the increase in density due to friction, normally expressed in pounds per gallon. Equivalent Circulating Density (when forward circulating) is defined as the apparent fluid density that results from adding annular friction to the actual fluid density in the well. [10]