When.com Web Search

  1. Ads

    related to: plumbing code distance between fixtures

Search results

  1. Results From The WOW.Com Content Network
  2. Air gap (plumbing) - Wikipedia

    en.wikipedia.org/wiki/Air_gap_(plumbing)

    According to the International Residential Code 2003, an air gap length must meet the requirements of being two times the effective inner diameter of the pipe (2×D) in order to be sufficient. [2] A standard widely use in the United States is: A112.1.2 Air Gaps in Plumbing Systems (For Plumbing Fixtures and Water-Connected Receptors)

  3. Uniform Plumbing Code - Wikipedia

    en.wikipedia.org/wiki/Uniform_Plumbing_Code

    The code has been widely used over the past five decades by jurisdictions throughout the United States and internationally. With the publication of the 2003 Edition of the Uniform Plumbing Code, another significant milestone was reached. For the first time in the history of the United States, a plumbing code was developed through a true ...

  4. International Plumbing Code - Wikipedia

    en.wikipedia.org/wiki/International_Plumbing_Code

    The IPC is the most widely used plumbing code in the United States and is also used as the basis for the plumbing code of several other countries [citation needed].Wide adoptions are important as they help reduce manufacturer and end-user costs by allowing the use of materials across a wide user base, thus allowing economies of scale in the production of materials used in construction.

  5. Plumbing code - Wikipedia

    en.wikipedia.org/wiki/Plumbing_code

    This code is also used as the basis for the plumbing codes of some other countries. Another model plumbing code published and utilized widely across the United States is the Uniform Plumbing Code , published by the International Association of Plumbing and Mechanical Officials ( IAPMO ), a multinational operation with offices in 13 nations.

  6. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Although it has been used in the past for connecting the drains of back-to-back fixtures (such as back-to-back sinks), some current codes—including the 2006 Uniform Plumbing Code in the United States—prohibit the use of this fitting for that purpose and require a double-fixture fitting (double combination wye) to minimize wastewater from ...

  7. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  8. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    Every fixture is required to have an internal or external trap to prevent sewer gases from entering a structure. Double trapping is prohibited by plumbing codes due to its susceptibility to clogging. In the U.S., every plumbing fixture must also be coupled to the system's vent piping. [1]

  9. Plumbing fixture - Wikipedia

    en.wikipedia.org/wiki/Plumbing_fixture

    The most common plumbing fixtures are: Bathtubs; Bidets; Channel drains; Drinking fountains; Showers; Sinks; Tap (connections for water hoses) . Tapware - an industry term for that sub-category of plumbing fixtures consisting of tap valves, also called water taps (British English) or faucets (American English), and their accessories, such as water spouts and shower heads.