When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Pacemaker crosstalk - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_crosstalk

    Crosstalk can only occur in a dual chamber or biventricular pacemaker. It happens less often in more recent models of dual chamber pacemakers due to the addition of a ventricular blanking period, which coincides with the atrial stimulus. This helps to prevent ventricular channel oversensing of atrial output.

  3. Pacemaker syndrome - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_syndrome

    Pacemaker syndrome is a condition that represents the clinical consequences of suboptimal atrioventricular (AV) synchrony or AV dyssynchrony, regardless of the pacing mode, after pacemaker implantation. [1] [2] It is an iatrogenic disease—an adverse effect resulting from medical treatment—that is often underdiagnosed.

  4. Pacemaker failure - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_failure

    Another study found that more than half of pacemaker complications occurred during the first 3 months after implantation. [2] Causes of pacemaker failure include lead related failure, unit malfunction, problems at the insertion site, failures related to exposure to high voltage electricity or high intensity microwaves, and a miscellaneous ...

  5. Pacemaker - Wikipedia

    en.wikipedia.org/wiki/Pacemaker

    A pacemaker, also known as an artificial cardiac pacemaker, is an implanted medical device that generates electrical pulses delivered by electrodes to one or more of the chambers of the heart. Each pulse causes the targeted chamber(s) to contract and pump blood, [ 3 ] thus regulating the function of the electrical conduction system of the heart .

  6. Cardiac contractility modulation - Wikipedia

    en.wikipedia.org/wiki/Cardiac_contractility...

    The FDA approved the OPTIMIZER Smart System, which delivers cardiac contractility modulation therapy, as indicated to improve 6-minute hall walk distance, quality of life, and functional status of NYHA Class III heart failure patients who remain symptomatic despite guideline directed medical therapy, who are in normal sinus rhythm, are not indicated for cardiac resynchronization therapy, and ...

  7. Ectopic pacemaker - Wikipedia

    en.wikipedia.org/wiki/Ectopic_pacemaker

    An ectopic pacemaker located in the atria is known as an atrial pacemaker and can cause the atrial contraction to be faster. [10] An ectopic pacemaker situated near the AV node and the septum is known as a junctional pacemaker. [11] The pacemaker that is operating in the ventricles is known as the ventricular. [12]

  8. HCN channel - Wikipedia

    en.wikipedia.org/wiki/HCN_channel

    HCN4 is the main isoform expressed in the sinoatrial node, but low levels of HCN1 and HCN2 have also been reported.The current through HCN channels, called the pacemaker current (I f), plays a key role in the generation and modulation of cardiac rhythmicity, [13] as they are responsible for the spontaneous depolarization in pacemaker action potentials in the heart.

  9. Cardiac action potential - Wikipedia

    en.wikipedia.org/wiki/Cardiac_action_potential

    [1] [2] This means that all atrial cells can contract together, and then all ventricular cells. Different shapes of the cardiac action potential in various parts of the heart Rate dependence of the action potential is a fundamental property of cardiac cells and alterations can lead to severe cardiac diseases including cardiac arrhythmia and ...