When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Flame ionization detector - Wikipedia

    en.wikipedia.org/wiki/Flame_ionization_detector

    To detect these ions, two electrodes are used to provide a potential difference. The positive electrode acts as the nozzle head where the flame is produced. The other, negative electrode is positioned above the flame. When first designed, the negative electrode was either tear-drop shaped or angular piece of platinum.

  3. Electrochemical gas sensor - Wikipedia

    en.wikipedia.org/wiki/Electrochemical_gas_sensor

    The sensors contain two or three electrodes, occasionally four, in contact with an electrolyte. The electrodes are typically fabricated by fixing a high surface area of precious metal onto the porous hydrophobic membrane. The working electrode contacts both the electrolyte and the ambient air to be monitored, usually via a porous membrane.

  4. Electrochemical stripping analysis - Wikipedia

    en.wikipedia.org/wiki/Electrochemical_stripping...

    For most standard tests, the working electrode is a bismuth or mercury film electrode (in a disk or planar strip configuration). The mercury film forms an amalgam with the analyte of interest, which upon oxidation results in a sharp peak, improving resolution between analytes. The mercury film is formed over a glassy carbon electrode. A mercury ...

  5. Eddy-current testing - Wikipedia

    en.wikipedia.org/wiki/Eddy-current_testing

    Tubing inspection is generally limited to non-ferromagnetic tubing and is known as conventional eddy current testing. Conventional ECT is used for inspecting steam generator tubing in nuclear plants and heat exchangers tubing in power and petrochemical industries. The technique is very sensitive to detect and size pits.

  6. Ion-selective electrode - Wikipedia

    en.wikipedia.org/wiki/Ion-selective_electrode

    An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor ) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential .

  7. Cyclic voltammetry - Wikipedia

    en.wikipedia.org/wiki/Cyclic_voltammetry

    The counter electrode, also known as the auxiliary or second electrode, can be any material that conducts current easily, will not react with the bulk solution, and has a surface area much larger than the working electrode. Common choices are platinum and graphite. Reactions occurring at the counter electrode surface are unimportant as long as ...

  8. Electron capture detector - Wikipedia

    en.wikipedia.org/wiki/Electron_capture_detector

    Electron capture detector developed by James Lovelock in the Science Museum, London Electron capture detector, Science History Institute. The electron capture detector is used for detecting electron-absorbing components (high electronegativity) such as halogenated compounds in the output stream of a gas chromatograph.

  9. Ionization chamber - Wikipedia

    en.wikipedia.org/wiki/Ionization_chamber

    The ionization chamber is the simplest type of gaseous ionisation detector, and is widely used for the detection and measurement of many types of ionizing radiation, including X-rays, gamma rays, alpha particles and beta particles.