Search results

  1. Results From The WOW.Com Content Network
  2. Multimeter - Wikipedia

    en.wikipedia.org/wiki/Multimeter

    Analog multimeter Digital multimeter. A multimeter (also known as a volt-ohm-milliammeter, volt-ohmmeter or VOM) [1] is a measuring instrument that can measure multiple electrical properties. [2] [3] A typical multimeter can measure voltage, resistance, and current, [4] in which case can be used as a voltmeter, ohmmeter, and ammeter.

  3. Open-circuit test - Wikipedia

    en.wikipedia.org/wiki/Open-circuit_test

    The open-circuit test, or no-load test, is one of the methods used in electrical engineering to determine the no-load impedance in the excitation branch of a transformer. The no load is represented by the open circuit, which is represented on the right side of the figure as the "hole" or incomplete part of the circuit.

  4. Continuity test - Wikipedia

    en.wikipedia.org/wiki/Continuity_test

    In electronics, a continuity test is the checking of an electric circuit to see if current flows (that it is in fact a complete circuit). A continuity test is performed by placing a small voltage (wired in series with an LED or noise-producing component such as a piezoelectric speaker ) across the chosen path.

  5. Growler (electrical device) - Wikipedia

    en.wikipedia.org/wiki/Growler_(electrical_device)

    to test series and interpoles (commutating) fields from a DC motor; to determine phasing and polarity in multiwinding armatures; to test rotors in rotating frequency changers, as well as in wound rotors; to test shorts between turns in taped coils before installation into an armature or a stator; as a low voltage isolation transformer

  6. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    The test is conducted on the high-voltage (HV) side of the transformer where the low-voltage (LV) side (or the secondary) is short-circuited. A wattmeter is connected to the primary side. An ammeter is connected in series with the primary winding. A voltmeter is optional since the applied voltage is the same as the voltmeter reading.

  7. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Condition monitoring of transformers in electrical engineering is the process of acquiring and processing data related to various parameters of transformers to determine their state of quality and predict their failure. This is done by observing the deviation of the transformer parameters from their expected values.

  8. Sweep frequency response analysis - Wikipedia

    en.wikipedia.org/wiki/Sweep_frequency_response...

    An initial SFRA test is carried out to obtain the signature of the transformer frequency response by injecting various discreet frequencies. This reference is then used for future comparisons. A change in winding position, degradation in the insulation, etc. will result in change in capacitance or inductance thereby affecting the measured curves.

  9. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    Thus it is still possible for an operator to be exposed to lethal voltages by touching multiple elements in the circuit. An isolation transformer provides maximum protection when the device is ungrounded. Connecting it to test equipment, for example, an oscilloscope or a benchtop multimeter, may ground the circuit.