Daylight harvesting systems are typically designed to maintain a minimum recommended light level. [1] This light level will vary according to the needs and use of the space; for example, the commonly recommended light level for offices is 500 Lux (or around 50 foot-candles) on the desktop.
Renovations completed in July 2014 improved the interiors and exterior, and reduced water and electric usage. Installations included high-efficiency water boilers, air-handling units, a building automation system, a rainwater harvesting tank, light fixtures, occupancy and daylight harvesting sensors, and low-flow water fixtures.
At night, ORNL HSL uses variable-intensity fluorescent lighting electronic control ballasts. As the sunlight gradually decreases at sunset, the fluorescent fixture is gradually turned up to give a near-constant level of interior lighting from daylight until after it becomes dark outside. HSL may soon become an option for commercial interior ...
This may include high efficiency fixtures and automated controls that make adjustments based on conditions such as occupancy or daylight availability. Lighting is the deliberate application of light to achieve some aesthetic or practical effect (e.g. illumination of a security breach). It includes task lighting, accent lighting, and general ...
An important property of light fixtures is the luminous efficacy or wall-plug efficiency, meaning the amount of usable light emanating from the fixture per used energy, usually measured in lumen per watt. A fixture using replaceable light sources can also have its efficiency quoted as the percentage of light passed from the "bulb" to the ...
[1] [3] To prevent this, fluorescent tubes are connected to the power line through a ballast. The ballast adds positive impedance (AC resistance) to the circuit to counteract the negative resistance of the tube, limiting the current. [1] Several American magnetic ballasts for fluorescent lamps. The top is a rapid start series autoregulator ...
To power an HMI bulb, special ballasts act as an ignitor to start the arc, and then regulate it by acting as a choke. Two types of ballasts exist: magnetic and electronic (square-wave or flicker-free). Magnetic ballasts are generally much heavier and bulkier than electronic ballasts, as they consist primarily of a network of large inductors ...
Running an energy-saving T8 tube with a ballast for T12 will reduce lamp life and can increase energy consumption. [9] Conversely, a T12 tube on a T8 ballast will usually draw too much power and so may burn out the ballast, unless it is within the range that particular ballast can compensate for.