  2. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    Group the cables involved in the ground loop into a bundle or snake. [3] The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end.

  3. File:Ground loop solution - isolation transformer.svg - Wikipedia

    en.wikipedia.org/wiki/File:Ground_loop_solution...

    The ground shield of S, along with the ground wire ("third wire") P in the components' power cord and the building's utility ground wiring G form a ground loop. One of the best ways to prevent such a ground loop is to insert an isolation transformer in the signal cable S, as shown. The transformer breaks the conductive path between the ground ...

  4. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    A grounded Faraday shield between the primary and the secondary greatly reduces the coupling of common-mode noise. This may be another winding or a metal strip surrounding a winding. Differential noise can magnetically couple from the primary to the secondary of an isolation transformer, and must be filtered out if a problem occurs.

  5. Galvanic isolation - Wikipedia

    en.wikipedia.org/wiki/Galvanic_isolation

    Everlight EL817 phototransistor opto-isolator in DIP-4 package Halo TG110-S050N2RL 10/100BASE-TX Ethernet pulse transformer in SO-16 package, with the underside shown on the right. Galvanic isolation is a principle of isolating functional sections of electrical systems to prevent current flow; no direct conduction path is permitted.

  6. Sheath current filter - Wikipedia

    en.wikipedia.org/wiki/Sheath_current_filter

    These are common mode chokes, damping high-frequency common-mode noise on cables. They block to high-frequency common-mode currents above about 50 MHz and affect the signal and the ground connection is not in terms of their Low frequency properties or protective function. Ferrite sheath current filters cannot effectively attenuate ground loop ...

  7. Isolated ground - Wikipedia

    en.wikipedia.org/wiki/Isolated_ground

    The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.