When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Boiling water reactor safety systems - Wikipedia

    en.wikipedia.org/wiki/Boiling_water_reactor...

    The Reactor Protection System (RPS) is a system, computerized in later BWR models, that is designed to automatically, rapidly, and completely shut down and make safe the Nuclear Steam Supply System (NSSS – the reactor pressure vessel, pumps, and water/steam piping within the containment) if some event occurs that could result in the reactor entering an unsafe operating condition.

  3. Nuclear reactor safety system - Wikipedia

    en.wikipedia.org/wiki/Nuclear_reactor_safety_system

    The Automatic Depressurization System (ADS) consists of a series of valves which open to vent steam several feet under the surface of a large pool of liquid water (known as the wetwell or torus) in pressure suppression type containments (typically used in boiling water reactor designs), or directly into the primary containment structure in ...

  4. Boiling water reactor - Wikipedia

    en.wikipedia.org/wiki/Boiling_water_reactor

    A boiling water reactor (BWR) is a type of nuclear reactor used for the generation of electrical power. It is the second most common type of electricity-generating nuclear reactor after the pressurized water reactor (PWR).

  5. Economic Simplified Boiling Water Reactor - Wikipedia

    en.wikipedia.org/wiki/Economic_Simplified...

    ESBWR's passive safety systems include a combination of three systems that allow for the efficient transfer of decay heat (created from nuclear decay) from the reactor to pools of water outside containment – the Isolation Condenser System, the Gravity Driven Cooling System, and the Passive Containment Cooling System. These systems utilize ...

  6. Reactor protection system - Wikipedia

    en.wikipedia.org/wiki/Reactor_protection_system

    The system can "trip" automatically (initiating a scram), or it can be tripped by the operators. Trips occur when the parameters meet or exceed the limit setpoint. A trip of the RPS results in full insertion (by gravity in pressurized water reactors or high-speed injection in boiling water reactors) of all control rods and shutdown of the reactor.

  7. GE BWR - Wikipedia

    en.wikipedia.org/wiki/GE_BWR

    The progenitor of the BWR line was the 5 MW Vallecitos Boiling Water Reactor (VBWR), brought online in October 1957. Six design iterations, BWR-1 through BWR-6, were introduced between 1955 and 1972. This was followed by the Advanced Boiling Water Reactor (ABWR) introduced in the 1990s and the Economic Simplified Boiling Water Reactor (ESBWR ...

  8. ‘Substantial’ safety violation alleged at SC nuclear plant ...

    www.aol.com/substantial-safety-violation-alleged...

    Officials at the V.C. Summer nuclear plant failed for 20 years to correct a problem of safety significance, federal regulators say. Now, Dominion Energy is in hot water with the federal government.

  9. Isolation condenser - Wikipedia

    en.wikipedia.org/wiki/Isolation_condenser

    The (E)SBWR reactors provide three days' supply of water in the pool. [1] Some older reactors also have IC systems, including Fukushima Dai-ichi reactor 1, however their water pools may not be as large. Under normal conditions, the IC system is not activated, but the top of the IC condenser is connected to the reactor's steam lines through an ...