When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles. Calculation

  3. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    Because the sprinkler orifices are open, the piping is at atmospheric pressure. To prevent the water supply pressure from forcing water into the piping, a "deluge valve" (a mechanically latched valve) is used in the water supply connection. It is a non-resetting valve, and stays open once tripped.

  4. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  5. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Deluge system Type of sprinkler system where sprinkler heads do not have individual valves, and the water (or other extinguishing agent) is disbursed from all sprinkler heads simultaneously when a central (or zoned) valve is triggered by a sensor (or manually). This is typically reserved for industrial areas where rapid fire spread must be ...

  6. Deluge gun - Wikipedia

    en.wikipedia.org/wiki/Deluge_gun

    A deluge gun, fire monitor, master stream or deck gun is an aimable controllable high-capacity water jet used for manual firefighting or automatic fire protection systems. Deluge guns are often designed to accommodate foam which has been injected in the upstream piping.

  7. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The majority of automatic fire sprinklers operate individually in a fire. Contrary to motion picture representation, the entire sprinkler system does not activate at the same time, unless the system is a special deluge type. [19] [20] Open orifice sprinklers are only used in water spray systems or deluge sprinklers systems.

  8. Deluge - Wikipedia

    en.wikipedia.org/wiki/Deluge

    A deluge is a large downpour of rain, often a flood. The Deluge refers to the flood narrative in the biblical book of Genesis. Deluge or Le Déluge may also refer to:

  9. Fire suppression system - Wikipedia

    en.wikipedia.org/wiki/Fire_suppression_system

    Fire suppression systems are governed by the codes under the National Fire Protection Association, also known as the NFPA.This organization writes codes, regulations, and recommendations on the proper installation and maintenance of these fire suppression systems.