  1. Results From The WOW.Com Content Network
  2. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  3. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The yellow P+N+E, 4h (120°) plug is a single phase connector that is in widespread use on the British Isles for 110 V building site and fairground applications. A popular model of this socket type is marketed under the brand name MK Commando [ 12 ] which leads some users to refer to all IEC 60309 sockets by the generic trademark Commando sockets .

  4. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    Single-phase motors may have taps to allow their use on either 208-volt or 240-volt supply. A single-phase load may be powered directly from a three-phase distribution transformer in two ways: by connection between one phase and neutral or by connection between two phases. These two give different voltages from a given supply.

  5. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    A receptacle with a green dot is a so-called "hospital grade" device; The primary reason to use a hospital-grade receptacle at a patient bed location is to ensure that a receptacle with a greater contact tension is provided to minimize possibilities that an attachment plug supplying medical or life support equipment may be disconnected because ...

  6. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    Current practice is to give separate services for single-phase and three-phase loads, e.g., 120 V split-phase (lighting etc.) and 240 V to 600 V three-phase (for large motors). However, many jurisdictions forbid more than one class for a premises' service, and the choice may come down to 120/240 V split-phase, 208 V single-phase or three-phase ...