There are three main classifications of fire rated walls: fire walls, fire barriers, and fire partitions. A firewall is an assembly of materials used to delay the spread of fire a wall assembly with a prescribed fire resistance duration and independent structural stability. This allows a building to be subdivided into smaller sections.
A fire-resistance rating typically means the duration for which a passive fire protection system can withstand a standard fire resistance test. This can be quantified simply as a measure of time, or it may entail other criteria, involving evidence of functionality or fitness for purpose.
The hole should be firestopped to restore the fire-resistance rating of the wall. Instead, it is filled with flammable polyurethane foam . A building code (also building control or building regulations ) is a set of rules that specify the standards for construction objects such as buildings and non-building structures .
Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]
A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.
Fire-retardant materials should not be confused with fire-resistant materials. A fire resistant material is one which is designed to resist burning and withstand heat. An example of a fire-resistant material is one which is used in bunker gear worn by firefighters to protect them from the flames of a burning building.
Fire blocking may also serve as bridging between framing elements, stiffening them against lateral buckling. [4] [5] Fire blocking or firestopping terminology was used interchangeably in code language from its first mention in the 1905 National Building Code (NBC), and requirements were expanded in the 1927 Uniform Building Code (UBC). Building ...
A building joint is a junction where building elements meet without applying a static load from one element to another. When one or more of these vertical or horizontal elements that meet are required by the local building code to have a fire-resistance rating, the resulting opening that makes up the joint must be firestopped in order to restore the required compartmentalisation.