Search results
Results From The WOW.Com Content Network
Diagram of a RAID 1 setup. RAID 1 consists of an exact copy (or mirror) of a set of data on two or more disks; a classic RAID 1 mirrored pair contains two disks.This configuration offers no parity, striping, or spanning of disk space across multiple disks, since the data is mirrored on all disks belonging to the array, and the array can only be as big as the smallest member disk.
RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.
The four-drive example is identical to a standard RAID 1+0 array, while the three-drive example is a software implementation of RAID 1E. The two-drive example is equivalent to RAID 1. [13] The driver also supports a "far" layout, in which all the drives are divided into f sections. All the chunks are repeated in each section but are switched in ...
Details of GPT support on 64-bit editions of Microsoft Windows [31] OS version Release date Platform Read and write support Boot support Note Windows XP 64-Bit Edition for Itanium systems, Version 2002 2001-10-25 IA-64: Yes Yes MBR takes precedence in hybrid configuration. Windows XP 64-Bit Edition, Version 2003 2003-03-28 IA-64: Yes Yes
RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.
Those RAID systems made their way to the consumer market, for users wanting the fault-tolerance of RAID without investing in expensive SCSI drives. Fast consumer drives make it possible to build RAID systems at lower cost than with SCSI, but most ATA RAID controllers lack a dedicated buffer or high-performance XOR hardware for parity calculation.
Versions 1 & 2 are for IDE drives without AHCI & RAID modes. v3.5.0: v4.x.x: Latest version in which MATRIX RAID mode is included on the named application Intel Application Accelerator RAID Edition. v5.x.x: Since this version the MATRIX RAID mode is included on the named application Intel Matrix Storage Manager, up to version 8.9. v5.5.0: 2005
In some RAID configurations, such as RAID 0, failure of a single member drive of the RAID array causes all stored data to be lost. In other RAID configurations, such as a RAID 5 that contains distributed parity and provides redundancy , if one member drive fails the data can be restored using the other drives in the array.