When.com Web Search

  1. Ad

    related to: industrial pump discharge head calculation formula

Search results

  1. Results From The WOW.Com Content Network
  2. Centrifugal pump selection and characteristics - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_pump_selection...

    Discharge Head, is the net head obtained at the outlet of a pump. For a centrifugal pump, the discharge pressure depends on the suction or inlet pressure as well, along with the fluid’s density. Thus, for the same flow rate of the fluid, we may have different values of discharge pressure depending on the inlet pressure.

  3. Total dynamic head - Wikipedia

    en.wikipedia.org/wiki/Total_dynamic_head

    In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.

  4. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  5. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws are useful as they allow the prediction of the head discharge characteristic of a pump or fan from a known characteristic measured at a different speed or impeller diameter. The only requirement is that the two pumps or fans are dynamically similar, that is, the ratios of the fluid forced are the same.

  6. Hydraulic head - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_head

    In fluid dynamics, head is a concept that relates the energy in an incompressible fluid to the height of an equivalent static column of that fluid. From Bernoulli's principle, the total energy at a given point in a fluid is the kinetic energy associated with the speed of flow of the fluid, plus energy from static pressure in the fluid, plus energy from the height of the fluid relative to an ...

  7. Euler's pump and turbine equation - Wikipedia

    en.wikipedia.org/wiki/Euler's_pump_and_turbine...

    With the help of these equations the head developed by a pump and the head utilised by a turbine can be easily determined. As the name suggests these equations were formulated by Leonhard Euler in the eighteenth century. [1] These equations can be derived from the moment of momentum equation when applied for a pump or a turbine.

  8. Cutthroat flume - Wikipedia

    en.wikipedia.org/wiki/Cutthroat_flume

    The free-flow discharge can be summarized as [3] = = Where Q is flow rate "C" is the free-flow coefficient; K is the free-flow length coefficient for the flume; H is the head at the primary point of measurement; n is the free-flow exponent "W" is the throat width

  9. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance.