When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Prothrombin time - Wikipedia

    en.wikipedia.org/wiki/Prothrombin_time

    The normal range for a healthy person not using warfarin is 0.8–1.2, and for people on warfarin therapy an INR of 2.0–3.0 is usually targeted, although the target INR may be higher in particular situations, such as for those with a mechanical heart valve. If the INR is outside the target range, a high INR indicates a higher risk of bleeding ...

  3. Clotting time - Wikipedia

    en.wikipedia.org/wiki/Clotting_time

    Adult male PT normal range is 9.6–11.8 seconds, while adult females' normal range is 9.5–11.3 seconds. [6] Internationalized normalized ratio (INR) is also a warfarin study, with therapeutic ranges of 2–3 for standard warfarin and 3–4.5 for high-dose warfarin. [ 6 ]

  4. Reference ranges for blood tests - Wikipedia

    en.wikipedia.org/wiki/Reference_ranges_for_blood...

    Reference ranges (reference intervals) for blood tests are sets of values used by a health professional to interpret a set of medical test results from blood samples. Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the ...

  5. Mixing study - Wikipedia

    en.wikipedia.org/wiki/Mixing_study

    If the problem is a simple factor deficiency, mixing the patient plasma 1:1 with plasma that contains 100% of the normal factor level results in a level ≥50% in the mixture (say the patient has an activity of 0%; the average of 100% + 0% = 50%). [3] The PT or PTT will be normal (the mixing study shows correction).

  6. Liver function tests - Wikipedia

    en.wikipedia.org/wiki/Liver_function_tests

    Prothrombin time (PT) and its derived measures of prothrombin ratio (PR) and INR are measures of the extrinsic pathway of coagulation. This test is also called "ProTime INR" and "INR PT". They are used to determine the clotting tendency of blood, in the measure of warfarin dosage, liver damage, and vitamin K status. [16]

  7. INR self-monitoring - Wikipedia

    en.wikipedia.org/wiki/INR_self-monitoring

    International normalized ratio (INR) which is a derivative of prothrombin time is a measurement of blood coagulation in the circulatory system. Both are used to determine the clotting rate of blood, which can be affected by anticoagulant usage, liver damage and Vitamin K levels. The preferred range of INR levels for a patient on anticoagulation ...

  8. Warfarin - Wikipedia

    en.wikipedia.org/wiki/Warfarin

    Warfarin should not be given to people with heparin-induced thrombocytopenia until platelet count has improved or normalised. [39] Warfarin is usually best avoided in people with protein C or protein S deficiency, as these thrombophilic conditions increase the risk of skin necrosis, which is a rare but serious side effect associated with ...

  9. Reference range - Wikipedia

    en.wikipedia.org/wiki/Reference_range

    The standard definition of a reference range for a particular measurement is defined as the interval between which 95% of values of a reference population fall into, in such a way that 2.5% of the time a value will be less than the lower limit of this interval, and 2.5% of the time it will be larger than the upper limit of this interval, whatever the distribution of these values.