A fire alarm system can vary dramatically in price and complexity, from a single panel with a detector and sounder in a small commercial property to an addressable fire alarm system in a multi-occupancy building. BS 5839 Part 1 categorizes fire alarm systems as: [21]
Smoke detector mounted on a ceiling. A smoke detector is a device that senses smoke, typically as an indicator of fire.Smoke detectors/alarms are usually housed in plastic enclosures, typically shaped like a disk about 125 millimetres (5 in) in diameter and 25 millimetres (1 in) thick, but shape and size vary.
From NFPA 72, 2002 Edition: “7.4.2.1* To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 7.4.2.2 through 7.4.2.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, whichever is greater ...
When the box is activated by turning a knob or pulling a hook, a spring-loaded wheel turns, tapping out a pulsed electrical signal corresponding to the box's number. [1] A receiver at fire headquarters announces the alarm through flashing lights or tones, or via a pen recorder, and the box number is matched to a list of box locations.
On 8 January 1997, the Malaysian Ministerial Cabinet agreed to change the coat of arms, flag, and name of the Malaysian Fire Services Department to the Malaysian Fire and Rescue Department. These were officially launched in a ceremony at the Genting Highlands Fire and Rescue Station in Pahang on 21 February 1997, by Prime Minister of Malaysia ...
Coded panels were the earliest type of central fire alarm control, and were made during the 1800s to the 1970s. A coded panel is similar in many ways to a modern conventional panel (described below), except each zone was connected to its own code wheel, which, depending on the way the panel was set up, would either do sets of four rounds of code until the initiating pull station was reset ...
Manual fire alarm activation requires human intervention, as distinct from automatic fire alarm activation such as that provided through the use of heat detectors and smoke detectors. It is, however, possible for call points/pull stations to be used in conjunction with automatic detection as part of the overall fire detection and alarm system .
The PASS device sounds a loud (95 decibel) [1] audible alert to notify others in the area that the firefighter is in distress. On a fireground, the sound of an activated PASS device indicates a true emergency and results in an immediate response to rescue the firefighters in distress.