When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Argentometry - Wikipedia

    en.wikipedia.org/wiki/Argentometry

    An example of back titration, the Volhard method, named after Jacob Volhard, involves the addition of excess silver nitrate to the analyte; the silver chloride is filtered, and the remaining silver nitrate is titrated against ammonium thiocyanate, [1] with ferric ammonium sulfate as an indicator which forms blood-red [Fe(OH 2) 5 (SCN)] 2+ at the end point:

  3. Titration - Wikipedia

    en.wikipedia.org/wiki/Titration

    Back titration is a titration done in reverse; instead of titrating the original sample, a known excess of standard reagent is added to the solution, and the excess is titrated. A back titration is useful if the endpoint of the reverse titration is easier to identify than the endpoint of the normal titration, as with precipitation reactions

  4. Kjeldahl method - Wikipedia

    en.wikipedia.org/wiki/Kjeldahl_method

    If boric acid (or some other weak acid) was used, direct acid–base titration is done with a strong acid of known concentration. HCl or H 2 SO 4 can be used. Indirect back titration is used instead if strong acids were used to make the standard acid solution: strong base of known concentration (like NaOH) is used to neutralize the solution. In ...

  5. Johan Kjeldahl - Wikipedia

    en.wikipedia.org/wiki/Johan_Kjeldahl

    In order to solve the problem of determining accurate nitrogen content in a sample, Kjeldahl developed a method which involves a two-step reaction: a distillation and a back titration. He found that ammonium salts can be produced by the reaction between organic compounds and sulfuric acid; this step is a digestion.

  6. Iodometry - Wikipedia

    en.wikipedia.org/wiki/Iodometry

    Iodometry, known as iodometric titration, is a method of volumetric chemical analysis, a redox titration where the appearance or disappearance of elementary iodine indicates the end point. Note that iodometry involves indirect titration of iodine liberated by reaction with the analyte, whereas iodimetry involves direct titration using iodine as ...

  7. Chemistry of ascorbic acid - Wikipedia

    en.wikipedia.org/wiki/Chemistry_of_ascorbic_acid

    This indicates the end-point of the titration. As an alternative, ascorbic acid can be treated with iodine in excess, followed by back titration with sodium thiosulfate using starch as an indicator. [40] This iodometric method has been revised to exploit the reaction of ascorbic acid with iodate and iodide in acid solution. Electrolyzing the ...

  8. Are Ozempic side effects more common in females? - AOL

    www.aol.com/ozempic-side-effects-more-common...

    Ozempic follows a dose titration schedule, where people start at a low 0.25 mg dosage and ramp up to their final maintenance dosage over 12–16 weeks. ... Once your diarrhea resolves, you can ...

  9. Thermometric titration - Wikipedia

    en.wikipedia.org/wiki/Thermometric_titration

    Fig. 15. Titration plot of back-titration of excess EDTA with Cu(II) in NH 3 /NH 4 Cl buffered solution. Direct EDTA titrations with metal ions are possible when reaction kinetics are fast, for example zinc, copper, calcium and magnesium. However, with slower reaction kinetics such as those exhibited by cobalt and nickel, back-titrations are used.