Search results

  1. Results From The WOW.Com Content Network
  2. Contact protection - Wikipedia

    en.wikipedia.org/wiki/Contact_protection

    Typical contact elements of an electromechanical relay or contactor. A “contact” is a pair of electrodes (typically, one moving; one stationary) designed to control electricity. Electromechanical switches, relays, and contactors “turn power on” when the moving electrode makes contact with the stationary electrode to carry current.

  3. Electric switchboard - Wikipedia

    en.wikipedia.org/wiki/Electric_switchboard

    It is an assembly of one or more panels, each of which contains switching devices for the protection and control of circuits fed from the switchboard. Several manufacturers make switchboards used in industry, commercial buildings, telecommunication facilities, oil and gas plants, data centers, health care, and other buildings, and onboard large ...

  4. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    Contact resistance values are typically small (in the microohm to milliohm range). Contact resistance can cause significant voltage drops and heating in circuits with high current. Because contact resistance adds to the intrinsic resistance of the conductors, it can cause significant measurement errors when exact resistance values are needed.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Receptacles protected in this manner or with a GFCI circuit breaker should be labeled "GFCI protected". (Outside North America these are referred to as a "Residual-current device" or RCD.) Arc-Fault Circuit Interrupter (AFCI) protection is required to protect nearly all finished areas of a home with the exception of bathrooms. This device ...

  6. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Also known as reclosers or autoreclosers, ACRs are essentially rated circuit breakers with integrated current and voltage sensors and a protection relay, optimized for use as a protection asset. Commercial ACRs are governed by the IEC 62271-111/IEEE Std C37.60 and IEC 62271-200 standards.

  7. Snubber - Wikipedia

    en.wikipedia.org/wiki/Snubber

    The coil diode clamp makes the relay turn off slower ( = /) and thus increases contact arc [clarification needed] if with a motor load which also needs a snubber. The diode clamp works well for coasting a uni-directional motor to a stop, but for bi-directional motors, a bipolar TVS is used.