The tonometer tip rests on the cornea with a constant appositional force of one gram. When the sensor is subjected to a change in pressure, the electrical resistance is altered and the tonometer's computer calculates a change in pressure according to the change in resistance. A complete measurement cycle requires about eight seconds of contact ...
The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.
Goldmann Applanation Tonometer attached with Slit lamp biomicroscope Goldmann Applanation Tonometer is an instrument that is based on Imbert-Fick law . It is considered to be the gold standard instrument for measurement of Intraocular pressure (IOP).
A patient in front of a tonometer. Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .
Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.
The Heidelberg Retinal Tomography is a diagnostic procedure used in ophthalmology.The Heidelberg Retina Tomograph (HRT) is an ophthalmological confocal point scanning laser ophthalmoscope [1] for examining the cornea and certain areas of the retina using different diagnostic modules (HRT retina, HRT cornea, HRT glaucoma).
To measure eye movement, pairs of electrodes are typically placed either above and below the eye or to the left and right of the eye. If the eye moves from center position toward one of the two electrodes, this electrode "sees" the positive side of the retina and the opposite electrode "sees" the negative side of the retina.
oculus dexter (right eye) OH Ocular history OMB Oculo motor balance ONH Optic nerve head Oph Ophthalmoscopy OS oculus sinister (left eye) OU oculus uterque (both eyes) PD Pupillary distance PERRLA Pupils equal, round, reactive to light and accommodation PH Pinhole see Pinhole occluder and Visual_acuity#Legal_definitions: PHNI Pinhole No Improvement