Search results
Results From The WOW.Com Content Network
The infrared absorption spectrum of NASA laboratory sulfur dioxide ice is compared with the infrared absorption spectra of ices on Jupiter's moon, Io credit NASA, Bernard Schmitt, and UKIRT. Absorption spectroscopy is useful in chemical analysis [5] because of its specificity and its quantitative nature. The specificity of absorption spectra ...
A Python library HAPI (HITRAN Application Programming Interface) has been developed which serves as a tool for absorption and transmission calculations as well as comparisons of spectroscopic data sets. HAPI extends the functionality of the main site, in particular, for the calculation of spectra using several types of line shape calculations ...
An infrared spectroscopy correlation table (or table of infrared absorption frequencies) is a list of absorption peaks and frequencies, typically reported in wavenumber, for common types of molecular bonds and functional groups.
Variable pathlength absorption spectroscopy uses a determined slope to calculate concentration. As stated above this is a product of the molar absorptivity and the concentration. Since the actual absorbance value is taken at many data points at equal intervals, background subtraction is generally unnecessary.
With the aid of these rules the UV absorption maximum can be predicted, for example in these two compounds: [8] In the compound on the left, the base value is 214 nm (a heteroannular diene). This diene group has 4 alkyl substituents (labeled 1,2,3,4) and the double bond in one ring is exocyclic to the other (adding 5 nm for an exocyclic double ...
The absorbance spectrum is plotted on a graph of absorbance vs. wavelength. [9] An Ultraviolet-visible spectroscopy#Ultraviolet–visible spectrophotometer will do all this automatically. To use this machine, solutions are placed in a small cuvette and inserted into the holder. The machine is controlled through a computer and, once it has been ...
The Elliott formula describes analytically, or with few adjustable parameters such as the dephasing constant, the light absorption or emission spectra of solids.It was originally derived by Roger James Elliott to describe linear absorption based on properties of a single electron–hole pair. [1]
The technique makes use of the atomic absorption spectrum of a sample in order to assess the concentration of specific analytes within it. It requires standards with known analyte content to establish the relation between the measured absorbance and the analyte concentration and relies therefore on the Beer–Lambert law.