Bi-Directional Static Load Test is a steadfast Maintained Load Test option for both large and small diameter piles that is widely used in the market. The main difference between a top-loaded maintained load test and a Bi-Directional is the location of the jack. One of the types of bi-directional method is YJACK method. [4]
Dynamic load testing takes a further step in analyzing the data and computing static capacity and resistance distribution. Dynamic pile monitoring takes advantage of the fact that, for driven piles, it is possible to compute the energy delivered to the pile, compression stresses at the pile top and toe and tension stresses along the shaft.
Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties
On construction sites, prior to the erection of a building, static load testing may use a large number of kentledge stacked onto a platform. This platform is used to drive piles into the ground beneath to test the integrity of the foundation. [1] [2]
The standard penetration test (SPT) is an in-situ dynamic penetration test designed to provide information on the geotechnical engineering properties of soil. This test is the most frequently used subsurface exploration drilling test performed worldwide. The test procedure is described in ISO 22476-3, ASTM D1586 [1] and Australian Standards AS ...
Dynamic load testing (or dynamic loading) is a method to assess a pile's bearing capacity by applying a dynamic load to the pile head (a falling mass) while recording acceleration and strain on the pile head. Dynamic load testing is a high strain dynamic test which can be applied after pile installation for concrete piles. For steel or timber ...
The test method consists of pushing an instrumented cone, with the tip facing down, into the ground at a controlled rate (controlled between 1.5 -2.5 cm/s accepted). The resolution of the CPT in delineating stratigraphic layers is related to the size of the cone tip, with typical cone tips having a cross-sectional area of either 10 or 15 cm 2 ...
Performance testing applies a safe working load (SWL), or other specified load, for a designated time in a governing test method, specification, or contract. Under the Lifting Operations and Lifting Equipment Regulations 1998 UK load testing after the initial test is required if a major component is replaced, if the item is moved from one ...