When.com Web Search

  1. Ad

    related to: wiring two lights in parallel

Search results

  1. Results From The WOW.Com Content Network
  2. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    In building wiring, multiway switching is the interconnection of two or more electrical switches to control an electrical load from more than one location.A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room.

  3. Series and parallel circuits - Wikipedia

    en.wikipedia.org/wiki/Series_and_parallel_circuits

    If the light bulbs are connected in parallel, the currents through the light bulbs combine to form the current in the battery, while the voltage drop is 12 volts across each bulb and they all glow. In a series circuit, every device must function for the circuit to be complete. If one bulb burns out in a series circuit, the entire circuit is broken.

  4. Circuit topology (electrical) - Wikipedia

    en.wikipedia.org/wiki/Circuit_topology_(electrical)

    A network with two components or branches has only two possible topologies: series and parallel. Figure 1.2. Series and parallel topologies with two branches. Even for these simplest of topologies, the circuit can be presented in varying ways. Figure 1.3. All these topologies are identical. Series topology is a general name.

  5. Daisy chain (electrical engineering) - Wikipedia

    en.wikipedia.org/wiki/Daisy_chain_(electrical...

    A graphic representation of a daisy chain A daisy garland, a chain of daisy flowers A series of devices connected in a daisy chain layout. In electrical and electronic engineering, a daisy chain is a wiring scheme in which multiple devices are wired together in sequence or in a ring, [1] similar to a garland of daisy flowers.

  6. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    If connected in series with the circuit it simply prevents reversed current, but if connected in parallel it can shunt the reversed supply, causing a fuse or other current limiting circuit to open. All semiconductor diodes have a threshold voltage – typically between 0.5 volt and 1 volt – that must be exceeded before significant current ...

  7. Bridge circuit - Wikipedia

    en.wikipedia.org/wiki/Bridge_circuit

    All are based on the same principle, which is to compare the output of two potential dividers sharing a common source. In power supply design, a bridge circuit or bridge rectifier is an arrangement of diodes or similar devices used to rectify an electric current, i.e. to convert it from an unknown or alternating polarity to a direct current of ...

  8. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...

  9. Relay logic - Wikipedia

    en.wikipedia.org/wiki/Relay_logic

    This also applied for pulling wire into the factory through conduit or in trays where each wire would have corresponding numbers. Wire labels were typically pieces of white tape with numbers or letters printed onto them and collected in small, pocket sized booklets. A number strip would be peeled out and wrapped around the wire near the end.