When.com Web Search

  1. Ad

    related to: refrigerant with gwp of 1 is called 5 seconds

Search results

  1. Results From The WOW.Com Content Network
  2. R-410A - Wikipedia

    en.wikipedia.org/wiki/R-410A

    However, like methane, R-410A has a global warming potential (GWP) that is appreciably worse than CO 2 (GWP = 1) for the time it persists. R-410A is a mixture of 50% HFC-32 and 50% HFC-125. HFC-32 has a 4.9 year lifetime and a 100-year GWP of 675 and HFC-125 has a 29-year lifetime and a 100-year GWP of 3500.

  3. List of refrigerants - Wikipedia

    en.wikipedia.org/wiki/List_of_refrigerants

    For example, R-22 has one carbon atom, one hydrogen atom (2−1 = 1), two fluorine atoms, and one chlorine atom (4−2−1 = 1), so it is chlorodifluoromethane, while R-134 has two carbon atoms (2−1 = 1), two hydrogen atoms (3−1 = 2), four fluorine atoms, and no chlorine atoms (6−2−4 = 0), so it is one of the tetrafluoroethanes. This ...

  4. 1-Chloro-3,3,3-trifluoropropene - Wikipedia

    en.wikipedia.org/wiki/1-Chloro-3,3,3...

    1-Chloro-3,3,3-trifluoropropene (HFO-1233zd) is the unsaturated chlorofluorocarbon with the formula HClC=C(H)CF 3.The compound exists as E- (cis-) and Z- (trans-) isomers.The trans-isomer of this colorless gas is of interest as a more environmentally friendly (lower GWP; global warming potential) refrigerant in air conditioners. [1]

  5. trans-1,3,3,3-Tetrafluoropropene - Wikipedia

    en.wikipedia.org/wiki/Trans-1,3,3,3-tetrafluoro...

    The use of R-134a is being phased out because of its high global warming potential (GWP). HFO-1234ze(E) itself has zero ozone-depletion potential (ODP=0), a very low global warming potential (GWP < 1 ), even lower than CO 2, and it is classified by ANSI/ASHRAE [4] as class A2L refrigerant (lower flammability (see below) and lower toxicity). [5]

  6. Natural refrigerant - Wikipedia

    en.wikipedia.org/wiki/Natural_refrigerant

    Refrigerants are typically evaluated on both their global warming potential (GWP) and ozone depletion potential (ODP).The GWP scale is standardized to carbon dioxide, where the refrigerant's value is the multiple of the heat that would be absorbed by the same mass of carbon dioxide over a period of time. [11]

  7. Working fluid selection - Wikipedia

    en.wikipedia.org/wiki/Working_fluid_selection

    The choice of working fluids is known to have a significant impact on the thermodynamic as well as economic performance of the cycle. A suitable fluid must exhibit favorable physical, chemical, environmental, safety and economic properties such as low specific volume (high density), viscosity, toxicity, flammability, ozone depletion potential (ODP), global warming potential (GWP) and cost, as ...

  8. R-469A - Wikipedia

    en.wikipedia.org/wiki/R-469A

    Thanks to the low GWP value, it fulfils the requirements of EU regulation 517/2014 on refrigerants for new systems even without the certificate of exemption otherwise necessary. Systems using the refrigerant R-469A up to 3.6 kg filling quantity are exempt from the Leak test in accordance with EU regulation 517/2014.

  9. Pentafluoroethane - Wikipedia

    en.wikipedia.org/wiki/Pentafluoroethane

    Due to its global warming potential (GWP) of 3500 times that of CO₂ and atmospheric lifetime of 29 years, it is included in the list of controlled substances of the Montreal Protocol. [ 4 ] [ 5 ] When introduced to the market HFC-125 was not considered safe for use in occupied spaces.