This absorption will cause the solution to change its colour from deep blue to light yellow when titrated with standardized thiosulfate solution. This indicates the end point of the titration. Iodometry is commonly used to analyze the concentration of oxidizing agents in water samples, such as oxygen saturation in ecological studies or active ...
Dissolved oxygen (D.O.) is widely used in water quality studies and routine operation of water reclamation facilities to analyze its level of oxygen saturation. In the test, an excess of manganese(II) salt, iodide (I − ) and hydroxide (OH − ) ions are added to a water sample causing a white precipitate of Mn(OH) 2 to form.
To this a solution containing potassium iodide, sodium thiosulfate, and starch is added. There are two reactions occurring simultaneously in the solution. In the first, slow reaction, iodine is produced: H 2 O 2 + 2 I − + 2 H + → I 2 + 2 H 2 O. In the second, fast reaction, iodine is reconverted to two iodide ions by the thiosulfate:
Sodium thiosulfate (sodium thiosulphate) is an inorganic compound with the formula Na 2 S 2 O 3 ·(H 2 O) x. Typically it is available as the white or colorless pentahydrate (x = 5), which is a white solid that dissolves well in water.
The elementary reaction responsible for water quantification in the Karl Fischer titration is oxidation of sulfur dioxide (SO 2) with iodine: . H 2 O + SO 2 + I 2 → SO 3 + 2 HI. This elementary reaction consumes exactly one molar equivalent of water vs. iodine.
The reduction reaction is analogous to the iodine reduction reaction. Treatment of tapwater requires between 0.1 and 0.3 grams of pentahydrated (crystalline) sodium thiosulfate per 10 L of water [citation needed]. Many animals are sensitive to chloramine, and it must be removed from water given to many animals in zoos. [citation needed]
The TSI slant is a test tube that contains agar, a pH-sensitive dye , 1% lactose, 1% sucrose, 0.1% glucose, [2] and sodium thiosulfate and ferrous sulfate or ferrous ammonium sulfate. All of these ingredients are mixed together, heated to sterility, and allowed to solidify in the test tube at a slanted angle.
Thermometric titrimetry offers a rapid, highly precise method for the determination of aluminium in solution. A solution of aluminium is conditioned with acetate buffer and an excess of sodium and potassium ions. Titration with sodium or potassium fluoride yields the exothermic precipitation of an insoluble alumino-fluoride salt.