When.com Web Search

  1. Ad

    related to: sweating evaporation mechanism heat pump system diagram pdf

Search results

  1. Results From The WOW.Com Content Network
  2. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    A thermal expansion valve or thermostatic expansion valve (often abbreviated as TEV, TXV, or TX valve) is a component in vapor-compression refrigeration and air conditioning systems that controls the amount of refrigerant released into the evaporator and is intended to regulate the superheat of the refrigerant that flows out of the evaporator ...

  3. Heat pump - Wikipedia

    en.wikipedia.org/wiki/Heat_pump

    In this system the solar thermal panel performs the function of the low temperature heat source and the heat produced is used to feed the heat pump's evaporator. [29] The goal of this system is to get high coefficient of performance and then produce energy in a more efficient and less expensive way.

  4. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]

  5. Absorption-compression heat pump - Wikipedia

    en.wikipedia.org/wiki/Absorption-compression...

    P-T Diagram showing the temperature gliding in binary heat pump. This behaviour increase the efficiency of ACHP Ammonia toxicity is the main drawback of ACHP. The main advantage with respect to compression heat pump is that the compression-absorption heat pumps allow the heat to be transfer with a temperature glide.

  6. Vapor-compression evaporation - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression_evaporation

    The compression ratio in a MVR unit does not usually exceed 1.8. At a compression ratio of 1.8, if the evaporation is performed at atmospheric pressure (0.101 MPa), the condensation pressure after compression will be 0.101 x 1.8 = 0.1818 [MPa]. At this pressure, the condensation temperature of the water vapor at the heat exchanger will be 390 K.

  7. Circulation evaporator - Wikipedia

    en.wikipedia.org/wiki/Circulation_evaporator

    The evaporator uses separate parts to create the overall system; a heat exchanger, separation tank and for the forced circulation system (as opposed to the natural circulation system) a circulation pump are standard although can be subject to change depending on the liquids properties of the mixtures being separated and specific design.

  8. Vapor-compression refrigeration - Wikipedia

    en.wikipedia.org/wiki/Vapor-compression...

    A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.

  9. Air source heat pump - Wikipedia

    en.wikipedia.org/wiki/Air_source_heat_pump

    An air source heat pump (ASHP) is a heat pump that can absorb heat from air outside a building and release it inside; it uses the same vapor-compression refrigeration process and much the same equipment as an air conditioner, but in the opposite direction. ASHPs are the most common type of heat pump and, usually being smaller, tend to be used ...