When.com Web Search

  1. Ad

    related to: direct burial fire alarm cable specification guide diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Direct-buried cable - Wikipedia

    en.wikipedia.org/wiki/Direct-buried_cable

    Cross-section of direct buried cable. Direct-buried cable (DBC) is a kind of communications or transmissions electrical cable which is especially designed to be buried under the ground without any other cover, sheath, or duct to protect it. [1] Most direct-buried cable is built to specific tolerances to heat, moisture, conductivity, and soil ...

  3. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Some types of conduit are approved for direct encasement in concrete. This is commonly used in commercial buildings to allow electrical and communication outlets to be installed in the middle of large open areas. For example, retail display cases and open-office areas use floor-mounted conduit boxes to connect power and communications cables.

  4. EN 54 - Wikipedia

    en.wikipedia.org/wiki/EN_54

    The EN 54 series of standards covers the following topics and product groups related to fire detection and fire alarm systems: [6] [7] Introduction: the introduction to the series of standards contains a diagram of a fire alarm system as well as numerous definitions of terms that are used in the other parts of the series of standards.

  5. Plenum cable - Wikipedia

    en.wikipedia.org/wiki/Plenum_cable

    The fire requirements on riser cable are not as strict. Thus, plenum cable can always replace riser cable, but riser cable cannot replace plenum cable in plenum spaces. Both plenum and riser cables commonly include a rope or polymer filament with high tensile strength, which helps support the weight of the cable when it is dangling in an open ...

  6. RG-6 - Wikipedia

    en.wikipedia.org/wiki/RG-6

    The number was assigned sequentially. The RG unit indicator is no longer part of the JETDS system (MIL-STD-196E) and cable sold today under the RG-6 label is unlikely to meet military specifications. In practice, the term RG-6 is generally used to refer to coaxial cables with an 18 AWG (1.024 mm) center conductor and 75 ohm characteristic ...

  7. Electrical cable - Wikipedia

    en.wikipedia.org/wiki/Electrical_cable

    6 inch (15 cm) outside diameter, oil-cooled cables, traversing the Grand Coulee Dam throughout. An example of a heavy cable for power transmission. Fire test in Sweden, showing fire rapidly spreading through the burning of cable insulation, a phenomenon of great importance for cables used in some installations. 500,000 circular mil (254 mm 2) single conductor power cable

  8. ANSI/TIA-568 - Wikipedia

    en.wikipedia.org/wiki/ANSI/TIA-568

    ANSI/TIA-568 is a technical standard for commercial building cabling for telecommunications products and services. The title of the standard is Commercial Building Telecommunications Cabling Standard and is published by the Telecommunications Industry Association (TIA), a body accredited by the American National Standards Institute (ANSI).

  9. Manual fire alarm activation - Wikipedia

    en.wikipedia.org/wiki/Manual_fire_alarm_activation

    Many modern fire alarm pull stations are single-action and only require the user to pull down a handle to sound the alarm. Other fire alarm pull stations are dual-action, and as such require the user to perform a second task before pulling down, such as lifting or pushing in a panel on the station or breaking a glass panel with an attached hammer.