When.com Web Search

  1. Ads

    related to: crossover cable wiring standard

Search results

  1. Results From The WOW.Com Content Network
  2. Ethernet crossover cable - Wikipedia

    en.wikipedia.org/wiki/Ethernet_crossover_cable

    A crossover cable may also be used to connect two hubs or two switches on their upstream ports. Because the only difference between the T568A and T568B pin and pair assignments are that pairs 2 and 3 are swapped, a crossover cable may be envisioned as a cable with one modular connector following T568A and the other T568B (see TIA/EIA-568 wiring ...

  3. ANSI/TIA-568 - Wikipedia

    en.wikipedia.org/wiki/ANSI/TIA-568

    A cable terminated according to T568A on one end and T568B on the other is a crossover cable when used with the earlier twisted-pair Ethernet standards that use only two of the pairs because the pairs used happen to be pairs 2 and 3, the same pairs on which T568A and T568B differ. Crossover cables are occasionally needed for 10BASE-T and ...

  4. Crossover cable - Wikipedia

    en.wikipedia.org/wiki/Crossover_cable

    Straight-through cables are used for most applications, but crossover cables are required in others. In a straight-through cable, pins on one end correspond exactly to the corresponding pins on the other end (pin 1 to pin 1, pin 2 to pin 2, etc.). Using the same wiring scheme at each end yields a straight-through

  5. Ethernet over twisted pair - Wikipedia

    en.wikipedia.org/wiki/Ethernet_over_twisted_pair

    A cable for Ethernet may be wired to either the T568A or T568B termination standard at both ends of the cable. Since these standards differ only in that they swap the positions of pairs 2 and 3 – the only pairs used by the formerly common 10BASE-T and 100BASE-TX – a cable with T568A wiring at one end and T568B at the other functions as a ...

  6. ISO/IEC 11801 - Wikipedia

    en.wikipedia.org/wiki/ISO/IEC_11801

    The Category 7 cable standard was ratified in 2002, and primarily introduced to support 10 gigabit Ethernet over 100 m of copper cabling. [2] It contains four twisted copper wire pairs, just like the earlier standards, terminated either with GG45 electrical connectors or with TERA connectors rated for transmission frequencies of up to 600 MHz.

  7. RS-422 - Wikipedia

    en.wikipedia.org/wiki/RS-422

    When used in relation to communications wiring, RS-422 wiring refers to cable made of 2 sets of twisted pair, often with each pair being shielded, and a ground wire. While a double-pair cable may be practical for many RS-422 applications, the RS-422 specification only defines one signal path and does not assign any function to it.