When.com Web Search

  1. Ads

    related to: transformer full load current calculation for motor unit diagram printable

Search results

  1. Results From The WOW.Com Content Network
  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  3. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    After reaching the rated current of the HV side, all three instruments reading (Voltmeter, Ammeter, and wattmeter readings) are recorded. The ammeter reading gives the primary equivalent of full load current I L. As the voltage applied for full load current in short circuit test on transformer is quite small compared to the rated primary ...

  4. Circle diagram - Wikipedia

    en.wikipedia.org/wiki/Circle_diagram

    The circle diagram can be drawn for alternators, synchronous motors, transformers, induction motors. The Heyland diagram is an approximate representation of a circle diagram applied to induction motors, which assumes that stator input voltage, rotor resistance and rotor reactance are constant and stator resistance and core loss are zero.

  5. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

  6. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  7. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque. One basic method to reduce the starting current is with a reduced voltage autotransformer with taps at 50%, 65% and 80% of the applied line voltage; once the motor is started the ...

  8. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The field produced by a single-phase winding can provide energy to a motor already rotating, but without auxiliary mechanisms the motor will not accelerate from a stop. A rotating magnetic field of steady amplitude requires that all three phase currents be equal in magnitude, and accurately displaced one-third of a cycle in phase.

  9. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.